Computational Optimization Techniques and Applications 2021
DOI: 10.5772/intechopen.96959
|View full text |Cite
|
Sign up to set email alerts
|

Highway PC Bridge Inspection by 3.95 MeV X-Ray/Neutron Source

Abstract: We have developed portable 950 keV/3.95 MeV X-ray/neutron sources and applied them to inspection of PC concrete thicker than 200 mm within reasonable measuring time of seconds - minutes. T-girder-, Box- and slab- bridges are considered. Now we are to start X-ray transmission inspection for highway PC bridge (box) by using 3.95 MeV X-ray sources in Japan in 2020. By obtaining X-ray transmission images of no-grout-filling in PC sheath and thinning of PC wires, we plan to carry out numerical structural analysis t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…Magnetic testing can detect the disconnection of iron rods or wires up to 300 mm in thickness. With a 400 kV X-ray tube, transmitted images of the PC sheath, wires, rods, and grout can be obtained up to 400 mm in thickness, but it takes approximately 1 h. Compared with the above existing methods, we explain and emphasize the advantage of our method using 950 keV/3.95 MeV X-ray sources [14][15][16]. With them, clear detection and visualization with 1 mm resolution of PC iron structures and grout filling at a depth of 400-1000 mm are possible within minutes.…”
Section: Review Of Existing Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Magnetic testing can detect the disconnection of iron rods or wires up to 300 mm in thickness. With a 400 kV X-ray tube, transmitted images of the PC sheath, wires, rods, and grout can be obtained up to 400 mm in thickness, but it takes approximately 1 h. Compared with the above existing methods, we explain and emphasize the advantage of our method using 950 keV/3.95 MeV X-ray sources [14][15][16]. With them, clear detection and visualization with 1 mm resolution of PC iron structures and grout filling at a depth of 400-1000 mm are possible within minutes.…”
Section: Review Of Existing Methodsmentioning
confidence: 99%
“…Compared with the above existing methods, we explain and emphasize the ad vantage of our method using 950 keV/3.95 MeV X-ray sources [14][15][16]. With them, clea detection and visualization with 1 mm resolution of PC iron structures and grout filling at a depth of 400-1000 mm are possible within minutes.…”
Section: Review Of Existing Methodsmentioning
confidence: 99%
See 3 more Smart Citations