Histologic effect of semiconductor diode laser transscleral cyclophotocoagulation on the normal equine eye

Abstract: The most appropriate site for equine TSCP appears to be 4 mm posterior to the dorso- and ventrotemporal limbus avoiding the 3 and 9 o'clock positions and using an initial energy setting of 2.25 J/site. This results in effective damage to the pars plicata while minimizing surgical complications such as retinal detachment and hemorrhage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
36
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(43 citation statements)
references
References 27 publications
6
36
1
Order By: Relevance
“…Diode laser TSCP was performed under general anesthesia using a semiconductor diode laser with an 810 nm G‐probe (Iridex DioVet®, Mountain View, CA, USA). Laser application sites were 4 mm posterior to the limbus in the dorsotemporal and ventrotemporal quadrants, avoiding the 3:00 and 9:00 positions, consistent with previous studies 5,6 . Laser treatment commenced with an initial energy of 1500 mW for 1500 ms as recommended by Morreale et al .…”
Section: Methodssupporting
confidence: 69%
See 2 more Smart Citations
“…Diode laser TSCP was performed under general anesthesia using a semiconductor diode laser with an 810 nm G‐probe (Iridex DioVet®, Mountain View, CA, USA). Laser application sites were 4 mm posterior to the limbus in the dorsotemporal and ventrotemporal quadrants, avoiding the 3:00 and 9:00 positions, consistent with previous studies 5,6 . Laser treatment commenced with an initial energy of 1500 mW for 1500 ms as recommended by Morreale et al .…”
Section: Methodssupporting
confidence: 69%
“…Laser treatment commenced with an initial energy of 1500 mW for 1500 ms as recommended by Morreale et al . and settings were adjusted to achieve audible popping at 25% of sites treated 6 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…TSCP induces coagulation necrosis of the nonpigmented ciliary epithelium, which reduces aqueous humour production and thus IOP (Morreale et al . ; Cavens et al . ; Gemensky‐Metzler et al .…”
mentioning
confidence: 99%
“…Photocoagulation, not photodisruption, is achieved with these settings [21] . Some surgeons treat only a small number of spots at a given time and repeat the treatment as needed to titrate IOP to the target pressure of < 20 mm Hg.…”
Section: Transscleral Laser Cyclophotocoagulationmentioning