2021
DOI: 10.1016/j.exer.2021.108475
|View full text |Cite
|
Sign up to set email alerts
|

Histologic validation of optical coherence tomography-based three-dimensional morphometric measurements of the human optic nerve head: Methodology and preliminary results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 43 publications
0
8
0
Order By: Relevance
“…Another possible explanation for the differences in rotation angle is that there is an error in our automated OCT measurement of rotation angle. To investigate this issue, the rotation angle was calculated using an independent automated and histologically validated OCT method (41). Similar results were observed suggesting strongly that the rotation angle is not larger in eyes of the high myopic group compared to eyes in the mild and no myopia group (data not shown, personal communication with Massimo Fazio-June 2020).…”
Section: Discussionmentioning
confidence: 55%
“…Another possible explanation for the differences in rotation angle is that there is an error in our automated OCT measurement of rotation angle. To investigate this issue, the rotation angle was calculated using an independent automated and histologically validated OCT method (41). Similar results were observed suggesting strongly that the rotation angle is not larger in eyes of the high myopic group compared to eyes in the mild and no myopia group (data not shown, personal communication with Massimo Fazio-June 2020).…”
Section: Discussionmentioning
confidence: 55%
“… 43 However, the differences between live and postmortem tissue in thickness and composition suggest the need for testing of living ONH. 84 We and others have developed a method to estimate LC strains in living eyes using OCT and digital volume correlation analysis of radial ONH images after suture lysis or trabeculectomy. 85 , 86 This research suggests that glaucoma eyes are not uniformly stiffer in LC strain response to IOP than non-glaucoma eyes.…”
Section: Discussionmentioning
confidence: 99%
“…Second, although the 3D reconstruction methodology that forms the morphological basis for the LC microstructure, sclera, and pia geometries is consistent with the tissue morphology in vivo, 105 there is some artifact due to tissue processing, fixation, and embedding for histologic reconstruction. 105 …”
Section: Discussionmentioning
confidence: 99%