2010
DOI: 10.1016/j.mpdhp.2009.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Histological microdissection in diagnostic and investigative pathology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 50 publications
0
6
0
1
Order By: Relevance
“…Coupled with a digital slide viewer, such a system can support fully remote pathology review of digitized WSIs, allowing NGS laboratories to widen their access to reviewing pathologists. Integration of SmartPath with automated microdissection systems 15 , 16 , 19 could allow for tissue extraction workflows which are almost entirely automated, with a pathologist needed only to approve or modify input parameters, and potentially be economically and clinically beneficial for NGS laboratories.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Coupled with a digital slide viewer, such a system can support fully remote pathology review of digitized WSIs, allowing NGS laboratories to widen their access to reviewing pathologists. Integration of SmartPath with automated microdissection systems 15 , 16 , 19 could allow for tissue extraction workflows which are almost entirely automated, with a pathologist needed only to approve or modify input parameters, and potentially be economically and clinically beneficial for NGS laboratories.…”
Section: Discussionmentioning
confidence: 99%
“…Laser-capture microdissection was introduced about two decades ago [11][12][13] , but has not been widely adopted in clinical laboratories because precise dissection of single tumor cells from FFPE slides is rarely necessary for clinical testing 14 . Lower resolution mechanical macrodissection systems have also been developed as more clinically pragmatic alternatives [15][16][17][18] . These systems can be combined with digital slide marking (digitally guided macrodissection), enabling integration with computer vision models for tumor enrichment 19,20 .…”
Section: Introductionmentioning
confidence: 99%
“…8 Furthermore, we did not examine the addition of laser capture microdissection, although this is well described. 14 Importantly, once a positive actin screen result has been obtained, the specimen is shown to contain a sufficient quantity and quality of RNA for a variety of subsequent RT-PCR reactions.…”
Section: Discussionmentioning
confidence: 99%
“…Laser capture microdissection (LCM) was introduced about two decades ago [14], but it has not been widely adopted in the clinical laboratory setting. LCM has been noted in multiple studies to diminish the yield and quality of retrieved material [9, 15-17], although others report that sample recovery is not impaired by the LCM process [18]. Even so, the precise dissection of single tumor cells from FFPE slides is seldom necessary for clinical molecular testing, whereas the rapid and cost effective retrieval of a sufficient DNA or RNA sample is paramount; therefore, lower resolution microdissection methods can be substituted for LCM.…”
Section: Introductionmentioning
confidence: 99%