2020
DOI: 10.1016/j.snb.2019.127408
|View full text |Cite
|
Sign up to set email alerts
|

Hook effect detection and detection-range-controllable one-step immunosensor for inflammation monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 40 publications
1
6
0
Order By: Relevance
“…At higher concentrations, the signals reach a plateau and start to decline. This phenomenon has been previously observed in several assays regarding the bioelectrical identification of molecules through membrane engineering [13,20,21]. It could be attributed to the saturation of the system when the concentration of the analyte exceeds a certain concentration.…”
Section: Optimizaton Of Membrane-engineered Sk-n-sh-s1 Protein Cells ...supporting
confidence: 53%
“…At higher concentrations, the signals reach a plateau and start to decline. This phenomenon has been previously observed in several assays regarding the bioelectrical identification of molecules through membrane engineering [13,20,21]. It could be attributed to the saturation of the system when the concentration of the analyte exceeds a certain concentration.…”
Section: Optimizaton Of Membrane-engineered Sk-n-sh-s1 Protein Cells ...supporting
confidence: 53%
“…In contrast, when 2250 Units/mL of ACE2 were used for increasing cell specification the results obtained displayed a decrease in the cell membrane potential. This effect, i.e., the decline of the biosensor response above low target analyte concentrations when the biorecognition element has been electroinserted at low or high concentrations (750/2250 Units/mL) is a frequent, yet not fully investigated phenomenon in molecular recognition through membrane engineering [37,38]. It is possibly due to either low level of responses at low ACE2 concentrations (even at higher S1 concentrations) or due to regional ion fluctuations of the cell membranes during the interaction with the analyte [39].…”
Section: Membrane Engineering Of Sk-n-sh Cells With Ace2 Triggers Distinct Bioelectric Alterations After Interaction With the Sars-cov-2 mentioning
confidence: 99%
“…11 To overcome the prozone effect, strategies such as diluting the sample prior to use 12 or computational modeling of test and control lines using real-time kinetics 13 A regression analysis was used to compare the known analyte concentration vs wavelength response alongside other statistical modeling to investigate linearity, prozone effect, and precision. 15 In particular, many previous works have demonstrated the presence of the prozone effect in C-reactive protein (CRP) as a case study. CRP is a well-investigated inflammatory biomarker, that is, an acute-phase protein produced by the liver, and rises rapidly in the instance of inflammation.…”
Section: ■ Introductionmentioning
confidence: 99%