How I manage drainage insufficiency on extracorporeal membrane oxygenation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
21
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 14 publications
0
21
0
Order By: Relevance
“…The sleeve, occluding some of drainage holes or drainage hole rows, may have decreased the inlet pressure at the level of the unobstructed holes. The lower inlet pressure (augmented negativity) would have increased the risk of collapse of the IVC on the cannula, arising drainage insufficiency, with swinging inlet pressure, drainage tubing “chattering,” and inconsistent EBF, 3 without any other evident cause and any substantial response to fluid challenge.…”
Section: To the Editormentioning
confidence: 99%
See 3 more Smart Citations
“…The sleeve, occluding some of drainage holes or drainage hole rows, may have decreased the inlet pressure at the level of the unobstructed holes. The lower inlet pressure (augmented negativity) would have increased the risk of collapse of the IVC on the cannula, arising drainage insufficiency, with swinging inlet pressure, drainage tubing “chattering,” and inconsistent EBF, 3 without any other evident cause and any substantial response to fluid challenge.…”
Section: To the Editormentioning
confidence: 99%
“…LETTERS TO THE EDITOR e472 of collapse of the IVC on the cannula, arising drainage insufficiency, with swinging inlet pressure, drainage tubing "chattering," and inconsistent EBF, 3 without any other evident cause and any substantial response to fluid challenge.…”
Section: Copyright © Asaio 2023mentioning
confidence: 99%
See 2 more Smart Citations
“…In patients requiring extracorporeal support due to acute respiratory distress syndrome, particularly in the COVID-19 population, known to be at high risk of barotrauma, 1,2 an acute decrease in the ECMO inlet pressure (increased negativity), 3,4 deteriorating EBF, compromizing therapy effectiveness, and increased post-membrane lung (return) pressure may suggest acute development of clinically significant pneumothorax, or significant worsening of preexisting pneumothorax, requiring prompt intervention to restore cardiovascular physiology and decrease intrathoracic pressure, allowing for EBF to be early reestablished. 5…”
mentioning