2019
DOI: 10.1080/14737159.2019.1643238
|View full text |Cite
|
Sign up to set email alerts
|

How MALDI-TOF mass spectrometry can aid the diagnosis of hard-to-identify pathogenic bacteria – the rare and the unknown

Abstract: Introduction: Ten years after its introduction into clinical microbiology, MALDI-TOF mass spectrometry has become the standard routine identification tool for bacteria in most laboratories. The technology has accelerated analyses and improved the quality of results. The greatest significance has been observed for bacteria that were challenging to be identified by traditional methods. Areas covered: We searched in existing literature (Pubmed) for reports how MALDI-TOF MS has contributed to identification of rar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
28
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
3
1

Relationship

1
9

Authors

Journals

citations
Cited by 46 publications
(29 citation statements)
references
References 110 publications
0
28
0
1
Order By: Relevance
“…Using the MBT IVD database, all the HACEK species could be accurately identified and differentiated, with an identification score higher than 2. Previous studies have stressed the usefulness of MALDI TOF ms for reliable identification of these species [ 30 ]. When tested against the FNRCT database, the HACEK and Brucella species displayed scores below 1.3 (unreliable identification).…”
Section: Discussionmentioning
confidence: 99%
“…Using the MBT IVD database, all the HACEK species could be accurately identified and differentiated, with an identification score higher than 2. Previous studies have stressed the usefulness of MALDI TOF ms for reliable identification of these species [ 30 ]. When tested against the FNRCT database, the HACEK and Brucella species displayed scores below 1.3 (unreliable identification).…”
Section: Discussionmentioning
confidence: 99%
“…However, sequencing is costly, has long turnaround times, and requires experienced personnel to circumvent technical traps; thus, it has only been implemented in reference laboratories or specialized centers (11). MALDI-TOF MS is a technology used for the identification of microorganisms (15, 16). It is a simple, reliable, and cost-effective method with a high degree of accuracy (17).…”
Section: Discussionmentioning
confidence: 99%
“…In the case report of Tarini et al, the causative agent of meningitis for a 50-year-old male patient was identified as S. mitis with a 99% probability (based on the VITEK 2 Compact ID/AST system), while sequencing results from cerebrospinal fluid confirmed S. suis as the true pathogen [ 99 ]. The increasing use of modern diagnostic tools (e.g., PCR, MALDI-TOF MS) and methods available for use directly from clinical specimens may further aid the identification biochemically inactive or unreliably-identified isolates [ 100 , 101 ]. A very recently published report by Olearo et al showed the first imported human case of S. suis infection in Switzerland: a 45-year-old woman bought and consumed raw pork meat imported from a small local farm in Moldova 24 h before flying back to Geneva, Switzerland.…”
Section: Discussionmentioning
confidence: 99%