HPLC-UV vs. UPLC-DAD for Estimation of Tinidazole, Benzyl Alcohol and Hydrocortisone Acetate Simultaneously with Tioconazole and Its Related Impurities in Bulk and Pharmaceutical Formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…The here-obtained LOD was similar to [ 22 24 ] or even 10-times lower than that obtained by other authors using HPLC–DAD [ 25 ] or CE-UV [ 26 ]. Although, the LOD obtained using the proposed sensor was higher than those obtained in other HPLC methods [ 18 , 27 ] it should be noted that electrochemical methods are simpler, faster and cheaper than those based on chromatography, and reagent consumption, specially of organic solvents, is much lower. The GC–MS methods present very low LOD values, as can be expected considering the characteristics of MS detector.…”
Section: Resultsmentioning
confidence: 75%
“…The here-obtained LOD was similar to [ 22 24 ] or even 10-times lower than that obtained by other authors using HPLC–DAD [ 25 ] or CE-UV [ 26 ]. Although, the LOD obtained using the proposed sensor was higher than those obtained in other HPLC methods [ 18 , 27 ] it should be noted that electrochemical methods are simpler, faster and cheaper than those based on chromatography, and reagent consumption, specially of organic solvents, is much lower. The GC–MS methods present very low LOD values, as can be expected considering the characteristics of MS detector.…”
Section: Resultsmentioning
confidence: 75%
“…The eluent gradient program was as follows: 0/50, 2/70, 5.6/70, 5.7/50, 7/50 (time [min]/%B). The established conditions and spectrophotometric detection in UV at a wavelength of 220 nm also allowed for the analysis of impurities present in the tested material [106]. Clotrimazole in substance and human plasma was analyzed on an Acquity BEH C-18 (50 × 2.1 mm, 1.7 µm) column and a mixture of water with 0.2% ammonium acetate and 0.1% formic acid (A) and methanol (B) in a volume ratio 18:82 (A:B).…”
Section: Antifungal and Anthelmintic Drugsmentioning
confidence: 99%
“…To separate and then determine the components of combination drugs, high- and ultrahigh-performance liquid chromatography (LC) [ 4 , 5 , 6 , 7 , 8 ], microemulsion LC [ 9 ], hydrophilic interaction LC [ 10 ], and capillary electrophoresis [ 11 , 12 ] are used. The preliminary separation of active components makes the analysis difficult, time-consuming, expensive, and often polluting.…”
Section: Introductionmentioning
confidence: 99%