2013
DOI: 10.1109/tasc.2012.2234317
|View full text |Cite
|
Sign up to set email alerts
|

HTS Coil Test Facility in a Large Bore 20 T Resistive Magnet at LNCMI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 12 publications
0
12
0
Order By: Relevance
“…a quench heater embedded in the coil winding and an array of voltage taps in its vicinity. The high current test probe, the high speed data acquisition techniques, the construction of a prototype coil ("HTS2") and the measurement results from T 2LOr2A-01 another coil have been reported earlier [12], [17]. We report here the outcome of the recent quench propagation tests on HTS2 performed in Grenoble.…”
Section: Quench Propagation In Hts Pancake Coil Under Magnetic Fieldmentioning
confidence: 93%
“…a quench heater embedded in the coil winding and an array of voltage taps in its vicinity. The high current test probe, the high speed data acquisition techniques, the construction of a prototype coil ("HTS2") and the measurement results from T 2LOr2A-01 another coil have been reported earlier [12], [17]. We report here the outcome of the recent quench propagation tests on HTS2 performed in Grenoble.…”
Section: Quench Propagation In Hts Pancake Coil Under Magnetic Fieldmentioning
confidence: 93%
“…Critical current measurements of several different tapes under various high magnetic fields can be found in the literature but they are mostly measured under specific magnetic field orientation, especially under parallel and perpendicular fields [19]. Some other orientations between these two specific cases can be also found but most of the time, the width of the tape is reduced in order to accommodate the measurement probe limitation [20,21].…”
Section: Experimental Setup and Measurement Probementioning
confidence: 99%
“…2) for £170 mm bore 20 T magnet at LNCMI. This probe has a longer sample length 90 mm and its high current capacity has been verified [20], and so the results obtained will be compared with those from the two new probes for the measurement validation.…”
Section: Experimental Set Upmentioning
confidence: 99%
“…The experimental procedure is described in [20] and it is performed in liquid helium bath. The transport current is simply ramped up to I c determined at the voltage criterion E c = 1 lV/cm with a ramp speed typically 1/20 of I c per second, a sufficient speed to obtain enough data points while avoiding heating to change the sample temperature.…”
Section: Experimental Set Upmentioning
confidence: 99%
See 1 more Smart Citation