1990
DOI: 10.1016/1359-0197(90)90302-x
|View full text |Cite
|
Sign up to set email alerts
|

Humidity effects on the dose response of radiachromic nylon film dosimeters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

1994
1994
2004
2004

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…Through a collaboration with NIST, a technique using radiachromic films was considered, tested, and calibrated at the APS [15]. Radiachromic films are nylon-based aminotriphenyl methane dye derivatives [22,23]. Upon exposure to ultraviolet light or ionizing radiation, the films undergo radiation-induced coloration by photoionization [22,24].…”
Section: Resources Required For Irradiationmentioning
confidence: 99%
“…Through a collaboration with NIST, a technique using radiachromic films was considered, tested, and calibrated at the APS [15]. Radiachromic films are nylon-based aminotriphenyl methane dye derivatives [22,23]. Upon exposure to ultraviolet light or ionizing radiation, the films undergo radiation-induced coloration by photoionization [22,24].…”
Section: Resources Required For Irradiationmentioning
confidence: 99%
“…The nylon-based material used in radiachromic films exhibits few or no environmental affects [12]. The films displayed a constant response for exposures in air and vacuum, as well as in the presence of ozone [12,13,20]. These stable conditions, along with simple handling procedures and no temperature dependence up to 50°C [15], led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the APS insertion devices.…”
Section: Radiachromic Film Dosimetersmentioning
confidence: 99%
“…Radiachromic film dosimeters are nylon-based aminotriphenyl methane dye derivatives [12,13]. Upon exposure to ultraviolet light or ionizing radiation, these films undergo radiation-induced coloration by photoionization [12,14].…”
Section: Radiachromic Film Dosimetersmentioning
confidence: 99%
“…The nylon-based material used in radiachromic films exhibits few or no environmental affects [12]. The films displayed a constant response for exposures in air and vacuum, as well as in the presence of ozone [12,13,20]. These stable conditions along with simple handling procedures and no temperature dependence up to 50°C [15], led to the implementation of radiachromic films as the technique of choice for measuring the absorbed doses received by the APS insertion devices.…”
Section: Radiachromic Filmsmentioning
confidence: 99%
“…Radiachromic films are nylon-based aminotriphenyl methane dye derivatives [12,13]. Upon exposure to ultraviolet light or ionizing radiation, these films undergo radiationinduced coloration by photoionization [12,14] The photochemical reaction that takes place when the radiachromic films are exposed to ultraviolet light or ionizing radiation is displayed in Figure 1.…”
Section: Radiachromic Filmsmentioning
confidence: 99%