2016
DOI: 10.1016/j.epsr.2015.11.043
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid state estimator considering SCADA and synchronized phasor measurements in VSC-HVDC transmission links

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…Specifically, classical HVDC links [119]- [120], voltage source converter-based HVDC (VSC-HVDC) links, and line commutated converter-based HVDC (LCC-HVDC) links are investigated. In [124]- [126], hybrid state estimators using SCADA and PMU measurements in AC/DC systems are studied. The state variable vector is extended by considering DC-side variables including voltage magnitudes and phase angles of voltage sources [124], nodal voltage magnitudes in DC networks, as well as state variables associated with VSC and DC-DC converters [125], and DC voltages, as well as firing and extinction angles [126].…”
Section: E Sse Using Other Types Of Measurementsmentioning
confidence: 99%
“…Specifically, classical HVDC links [119]- [120], voltage source converter-based HVDC (VSC-HVDC) links, and line commutated converter-based HVDC (LCC-HVDC) links are investigated. In [124]- [126], hybrid state estimators using SCADA and PMU measurements in AC/DC systems are studied. The state variable vector is extended by considering DC-side variables including voltage magnitudes and phase angles of voltage sources [124], nodal voltage magnitudes in DC networks, as well as state variables associated with VSC and DC-DC converters [125], and DC voltages, as well as firing and extinction angles [126].…”
Section: E Sse Using Other Types Of Measurementsmentioning
confidence: 99%
“…Other works incorporate the DC measurements using the non-linear power balance equations and use the modulation index as a measurement to link the DC voltage to the AC voltage magnitude [14]. [15] uses the power balance while ignoring the converter losses and iteratively solves the WLS SE using the partial derivative of the measurement equations.…”
Section: A State Estimation For Hybrid Ac/dc Gridsmentioning
confidence: 99%
“…Different from the communication system for SCADA [22], the agents exchange their judgment and decision instead of the original observation data. Hence, the requirement on communication bandwidth is reduced greatly.…”
Section: The Mas-basde Self-healing Frameworkmentioning
confidence: 99%