2016
DOI: 10.1039/c5ay02774h
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic interaction liquid chromatography for separation and determination of pyrrolidinium ionic liquid cations

Abstract: The separation and detection of pyrrolidinium cations by hydrophilic interaction liquid chromatography with indirect ultraviolet detection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…The mobile phase of 0.5 mmol/L [EMIm][BF 4 ]/7.0 mmol/L glycolic acid/acetonitrile (91:9, v/v) were used to investigate the influence of column temperature (25,30,35, and 40ЊC) on the retention times of Li + , Na + , K + , and NH 4 + . It can be seen that the retention times of Li + and Na + were lengthened with the increase of column temperature, the process was an endothermic process.…”
Section: Effect Of Column Temperaturementioning
confidence: 99%
See 1 more Smart Citation
“…The mobile phase of 0.5 mmol/L [EMIm][BF 4 ]/7.0 mmol/L glycolic acid/acetonitrile (91:9, v/v) were used to investigate the influence of column temperature (25,30,35, and 40ЊC) on the retention times of Li + , Na + , K + , and NH 4 + . It can be seen that the retention times of Li + and Na + were lengthened with the increase of column temperature, the process was an endothermic process.…”
Section: Effect Of Column Temperaturementioning
confidence: 99%
“…ILs as the mobile phase additives are more and more used in the separation of LC [21,22]. An active research is found in many reports on the role of ILs to modify the retention of different types of solutes [23][24][25]. Based on their UV absorption, imidazolium ILs have been applied as background reagents determination of ILs cations for the HPLC [26] and IC [27] using IUV.…”
mentioning
confidence: 99%
“…Moreover, compared with normal‐phase chromatography, the mobile phase of HILIC is compatible with mass spectrometry (MS) (especially electrospray ionization mass spectrometry), and thus, it improves the detection sensitivity . Thus, HILIC has been widely applied in various fields, including pharmaceutical analysis, food analysis, biomedical science, analytical chemistry, etc. In addition, many new stationary phases have been developed by introducing a variety of functional groups like hydrophilic macromolecules and ionic liquids, which can provide wider ranges of applications for HILIC …”
Section: Introductionmentioning
confidence: 99%
“…Due to their unique properties, their use has attracted considerable interest, including an increasing number of publications on their use in preparing stationary phases of HPLC . An active research is found in many reports on the role of ILs to modify the retention of different types of solutes in LC . Based on their UV absorption, imidazolium ILs have been applied as background reagents for determination of IL cations in the HPLC and IC with UV indirect detection.…”
Section: Introductionmentioning
confidence: 99%