Hyperconcentrated platelets stored in additive solution: aspects on productivity and in vitro quality

Abstract: TRIMA V4 is a suitable device for the collection of DPs. Nevertheless, improvements are desirable to further increase the ability to concentrate PLTs at very high levels. The storage of apheresis-derived PLTs in PAS III-M is a very promising approach, even at a plasma carryover of < 30%.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
35
0
1

Year Published

2006
2006
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(42 citation statements)
references
References 34 publications
6
35
0
1
Order By: Relevance
“…The hyperconcentration may have resulted in platelet damage, and therefore we evaluated the Trima system, which uses a different collection system and hyperconcentration method. 8,12,13 Unfortunately, there were no differences in poststorage platelet viability regardless of the Terumo BCT system that was used (Tables 1 and 3; Figure 1A-B).…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The hyperconcentration may have resulted in platelet damage, and therefore we evaluated the Trima system, which uses a different collection system and hyperconcentration method. 8,12,13 Unfortunately, there were no differences in poststorage platelet viability regardless of the Terumo BCT system that was used (Tables 1 and 3; Figure 1A-B).…”
Section: Discussionmentioning
confidence: 97%
“…12,13 For the Haemonetics studies, the platelets were elutriated with PAS instead of plasma during collection by sterile docking a Haemonetics bag (Effluent #692) containing PAS to the collection set. The operator would unclamp and, as appropriate, clamp the tubing to the #692 bag to permit surging with PAS.…”
Section: Pas Plateletsmentioning
confidence: 99%
“…Es ist möglich, auch ATK plasmareduziert in additiver Lösung herzustellen [64][65][66][67][68][69] [90]. In diesen Studien wurden fast ausschließlich ATK verwendet [83,87,95].…”
Section: Hb-gehalt Der Ekunclassified
“…Furthermore, the use of platelet additive solution could help to improve storage conditions and thus increase the shelf life of the platelets while maintaining the viability and hemostatic function. [23] The present study was done to assess the in vitro function of random donor platelets stored for 7 days in composol platelet additive solution at 22°C.…”
Section: Introductionmentioning
confidence: 99%