2010
DOI: 10.1002/biot.200900074
|View full text |Cite
|
Sign up to set email alerts
|

In vitro liver model using microfabricated scaffolds in a modular bioreactor

Abstract: Hepatocyte function on 3-D microfabricated polymer scaffolds realised with the pressure-activated microsyringe was tested under static and dynamic conditions. The dynamic cell culture was obtained using the multicompartment modular bioreactor system. Hepatocyte cell density, glucose consumption, and albumin secretion rate were measured daily over a week. Cells seeded on scaffolds showed an increase in cell density compared with monolayer controls. Moreover, in dynamic culture, cell metabolic function increased… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
46
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
8
1

Relationship

6
3

Authors

Journals

citations
Cited by 39 publications
(52 citation statements)
references
References 38 publications
5
46
1
Order By: Relevance
“…These velocities are consistent with those typically reported for micro-fluidic cell culture devices [42]. For the MCmB model, the v in was set to 3.82 × 10 −3 m/s (corresponding to 180 μL/min inflow), on the basis of previous experiments with this bioreactor [31,[62][63][64][65][66]. Table 4.…”
Section: Model Implementationsupporting
confidence: 64%
“…These velocities are consistent with those typically reported for micro-fluidic cell culture devices [42]. For the MCmB model, the v in was set to 3.82 × 10 −3 m/s (corresponding to 180 μL/min inflow), on the basis of previous experiments with this bioreactor [31,[62][63][64][65][66]. Table 4.…”
Section: Model Implementationsupporting
confidence: 64%
“…Aft er equilibration the sensors were extremely stable in medium with a maximum of 4% deviation in |Z p | for up to 7 days. In the presence of cell culture media the impedance decreases with frequency up to 2MHz; this is rather diff erent than the results reported by Lo et al [57] and Huang et al [58] where between 50 kHz and 1MHz the measured impedance without cells is constant and very low in magnitude. It should be noted that the impedance measurement set up is slightly diff erent here because the conductive substrate completely covers the surface and there are no insulating islands to contribute to large capacitive eff ects.…”
Section: Membrane Impedance Measurementcontrasting
confidence: 78%
“…LB1 is a single flow transparent bioreactor with an internal hydrodynamic design which ensures a low wall shear stress for high fluid turnover rates. The bioreactor is an upgrade of the MCmB (multi-compartmental modular bioreactor), which has been successfully used with hepatocytes [21,22]. The geometry of LB1 differs slightly from the MCmB, to increase the optical transparency of the system and enable optical imaging during the experiment.…”
Section: The Livebox1 Bioreactormentioning
confidence: 99%