2020
DOI: 10.1107/s1600577520011388
|View full text |Cite
|
Sign up to set email alerts
|

THORONDOR: a software for fast treatment and analysis of low-energy XAS data

Abstract: THORONDOR is a data treatment software with a graphical user interface (GUI) accessible via the browser-based Jupyter notebook framework. It aims to provide an interactive and user-friendly tool for the analysis of NEXAFS spectra collected during in situ experiments. The program allows on-the-fly representation and quick correction of large datasets from single or multiple experiments. In particular, it provides the possibility to align in energy several spectral profiles on the basis of user-defined reference… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 51 publications
0
11
0
Order By: Relevance
“…After the reduction step in H 2 , the sample was cooled down to room temperature in He gas flow prior to the oxidation step in 10%O 2 /He. Data treatment, involving energy alignment, background subtraction using an asymmetric least squares fitting routine, and normalization to the total area under the curves, was performed by using the recently developed THORONDOR code …”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…After the reduction step in H 2 , the sample was cooled down to room temperature in He gas flow prior to the oxidation step in 10%O 2 /He. Data treatment, involving energy alignment, background subtraction using an asymmetric least squares fitting routine, and normalization to the total area under the curves, was performed by using the recently developed THORONDOR code …”
Section: Experimental Methodsmentioning
confidence: 99%
“…Data treatment, involving energy alignment, background subtraction using an asymmetric least squares fitting routine, and normalization to the total area under the curves, was performed by using the recently developed THORONDOR code. 57…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Importantly, only an optical model of parallel aromatic groups reproduced experiment, while a herringbone orientation model failed. A second similar analysis on approximately 5 monolayers of a conjugated small molecule on an Au 111 substrate confirmed the flat‐lying molecules and compared DFT‐derived versus NEXAFS‐spectroscopy‐derived optical models 186 . In the future, it may be helpful to combine both ab‐initio (DFT) information with experimental measurements to generate the most accurate optical models.…”
Section: Rsoxs Examplesmentioning
confidence: 77%
“…These work very well for scattering data reduction and model fitting, but are generally not well equipped and optimized to deal with spectroscopy, and the process of processing each energy independently can be logistically difficult for large hyperspectral datasets. Similarly, while spectroscopy solutions 44,110,111 are excellent for analyzing and visualizing the spectroscopic axis of hyperspectral data, they are not well equipped and optimized to deal with scattering datasets and are usually designed to deal with only a handful of channels of data, not a 2D scattering image or 1D scattering profiles at each energy. This has meant that generally each RSoXS experiment is analyzed with custom software.…”
Section: Analysis Softwarementioning
confidence: 99%
“…NEXAFS data were acquired after 15 min at each selected temperature point. Data treatment, involving energy alignment, background subtraction using an asymmetric least square fitting routine and normalization to the total area under the curves, was performed by using the recently developed THORONDOR code [60]. The relative concentration of each oxidation state was calculated based on linear combination fit (LCF) analysis using as reference NEXAFS spectra of model Co and Mn oxides obtained from previous experiments [48] or from the literature [61].…”
Section: In Situ Nexafs At 1bar Under Model Redox Conditionsmentioning
confidence: 99%