2016
DOI: 10.1109/tdei.2015.005426
|View full text |Cite
|
Sign up to set email alerts
|

Ice flashover performance and its characterization parameter of composite insulator with booster sheds

Abstract: In order to investigate the ice flashover performance and characterization parameter of composite insulators, numerical calculation was applied to simulate the icicle growth and make comparison with different structures. It was found that the number of booster sheds existed an optimized range and saturated icicle bridged degree of big sheds or booster sheds could be considered as the characterization parameter to reflect the ice flashover voltage. Booster sheds applied to 500 kV composite insulators show its a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 23 publications
0
12
0
Order By: Relevance
“…In order to obtain melting ice, the door of the climate room was opened to let the temperature increase above 0 °C. In the existing studies, the voltage distributions of the iced insulators were obtained by simulations [19][20][21], but the simulated results have not been validated by experiments. In this paper, a 50 kV voltage Ua was applied to the high-voltage terminal of the test insulators.…”
Section: Electric and Flashover Performance Evaluation Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…In order to obtain melting ice, the door of the climate room was opened to let the temperature increase above 0 °C. In the existing studies, the voltage distributions of the iced insulators were obtained by simulations [19][20][21], but the simulated results have not been validated by experiments. In this paper, a 50 kV voltage Ua was applied to the high-voltage terminal of the test insulators.…”
Section: Electric and Flashover Performance Evaluation Methodsmentioning
confidence: 99%
“…The detailed test procedure to determine U50 is shown in [23,29]. Provided that N is the number of test results, the first flashover voltage is marked with U1, the second one U2,and the Nth Un, U50 can be expressed as: In the existing studies, the voltage distributions of the iced insulators were obtained by simulations [19][20][21], but the simulated results have not been validated by experiments. In this paper, a 50 kV voltage U a was applied to the high-voltage terminal of the test insulators.…”
Section: Electric and Flashover Performance Evaluation Methodsmentioning
confidence: 99%
See 3 more Smart Citations