Image intensifier distortion influences a surgeon’s ability to aim guidewires during orthopaedic procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 14 publications
1
7
0
Order By: Relevance
“…Both central and peripheral S‐distortion artifacts are numerically calculated, and, if interested, the maximum deviated distance can be estimated by multiplying the D/L ratio with the length (L) of the 200‐mm rod phantom. The results will be close to the reported deviation of approximately 1 cm at the peripheral of 12‐inch fluoroscopic images 5,12 …”
Section: Discussionsupporting
confidence: 88%
See 1 more Smart Citation
“…Both central and peripheral S‐distortion artifacts are numerically calculated, and, if interested, the maximum deviated distance can be estimated by multiplying the D/L ratio with the length (L) of the 200‐mm rod phantom. The results will be close to the reported deviation of approximately 1 cm at the peripheral of 12‐inch fluoroscopic images 5,12 …”
Section: Discussionsupporting
confidence: 88%
“…The results will be close to the reported deviation of approximately 1 cm at the peripheral of 12-inch fluoroscopic images. 5,12 Using the magnetic flux density at an II's entrance surface as the representative magnetic field experienced by the II, the fitted linear regression equations of Sdistortion quantification metrics in response to magnetic flux density can be used to anticipate the degree of 'unpredictable' S-distortion with high confidence, and determine if further S-distortion mitigation strategies are necessary before any undesirable surgical outcomes happen.…”
Section: Discussionmentioning
confidence: 99%
“…The slight deviation of the measured MP values relative to the direct measurements may be due to incomplete orthogonal rendering of the reference ring as it is only depicted partially on the intensifier images. Another reason for the measurement deviation might be explained by the problem of image intensifier distortion that occurs with intraoperative imaging [ 25 ]. The obtained images in this study were not corrected for distortion.…”
Section: Discussionmentioning
confidence: 99%
“…for each projection angle in the images series corrected using a static approach. Figure obtained from Sanctorum et al [17] Next, different values of 𝑁 ∈ [3,360] were chosen to estimate the dynamic distortion behavior of the platform. For each choice of 𝑁 , the corresponding number of frames were selected from the series of the DIC pattern, which were consecutively used in the DIC analysis to obtain the distorted coordinate surfaces.…”
Section: A) Residual Error In Projectionsmentioning
confidence: 99%
“…Although x-ray image intensifier (XRII) distortion is a long-known and well-studied issue [1,2] , it remains an important problem in XRII-based imaging to this day [3] . In small animal related biomechanical research, for example, the number of stereoscopic x-ray imaging facilities is rising exponentially [4] , where XRIIs are preferred over flat-panel detectors because of their ability to be combined with high-speed cameras, necessary to monitor fast movements [5] .…”
Section: Introductionmentioning
confidence: 99%