2014
DOI: 10.4161/intv.28210
|View full text |Cite
|
Sign up to set email alerts
|

IMART software for correction of motion artifacts in images collected in intravital microscopy

Abstract: Intravital microscopy is a uniquely powerful tool, providing the ability to characterize cell and organ physiology in the natural context of the intact, living animal. With the recent development of high-resolution microscopy techniques such as confocal and multiphoton microscopy, intravital microscopy can now characterize structures at subcellular resolution and capture events at sub-second temporal resolution. However, realizing the potential for high resolution requires remarkable stability in the tissue. W… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
29
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 24 publications
(29 citation statements)
references
References 37 publications
0
29
0
Order By: Relevance
“…The geometric transformation required to correct these deformations is often non-rigid and non-linear. Therefore, it cannot be expressed under a matrix form and requires a sophisticated processing that can be achieved by deformation of an iteratively deformed grid of control points [63].…”
Section: Non-rigid Deformationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The geometric transformation required to correct these deformations is often non-rigid and non-linear. Therefore, it cannot be expressed under a matrix form and requires a sophisticated processing that can be achieved by deformation of an iteratively deformed grid of control points [63].…”
Section: Non-rigid Deformationsmentioning
confidence: 99%
“…In particular, a strategy based on the use of a uniform grid of control points to reduce distortion-induced dissimilarities between sequential images in IVM has been developed and fruitfully used for lung IVM [28,63,65,66]. The underlying premise is that two consecutive frames of either a z-stack or a time-series would be very similar without motion artifacts [63].…”
Section: Non-rigid Deformationsmentioning
confidence: 99%
“…Additionally, gating the image collection to respiration can minimize the motion artifacts in tissues such as the lung 25,26 . Finally, motion-induced distortions can be eliminated from the collected images using various methods of digital image analysis [27][28][29][30][31] .…”
Section: ) Optimized Probes For Tplsmmentioning
confidence: 99%
“…This technique initially starts with a rigid registration step and then uses localized non-rigid registration. The four spectral channels are transformed to grayscale images using the spectral channel weights described in [20,21]. First, rigid registration is used to reduce global motion artifacts between images.…”
Section: Interpolation and 3d Non-rigid Registrationmentioning
confidence: 99%
“…We use the non-rigid method described in our previous work [20,21] because this method can effectively eliminate 3D non-rigid motion artifacts between focal slices. This technique initially starts with a rigid registration step and then uses localized non-rigid registration.…”
Section: Interpolation and 3d Non-rigid Registrationmentioning
confidence: 99%