1989
DOI: 10.1016/s0378-4347(00)84474-6
|View full text |Cite
|
Sign up to set email alerts
|

Immobilized enzyme reactors for detection systems in high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

1991
1991
2012
2012

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(5 citation statements)
references
References 42 publications
0
4
0
1
Order By: Relevance
“…In this way sensitivity of the detection system is considerably enhanced and determination of trace components in complex matrices therefore become possible. However, some drawbacks such as band broadening due to non-specific binding to the enzyme [7] and the influence of the flow rate on the substrate conversion efficiency in the case of specific mass transfer regimen can limit the application of IMERs in HPLC. Infact when microparticulate supports are employed, the system operates under diffusionlimiting conditions because the substrate reaches the catalytic sites more slowly than the rate of enzymatic product formation [8].…”
Section: Introductionmentioning
confidence: 99%
“…In this way sensitivity of the detection system is considerably enhanced and determination of trace components in complex matrices therefore become possible. However, some drawbacks such as band broadening due to non-specific binding to the enzyme [7] and the influence of the flow rate on the substrate conversion efficiency in the case of specific mass transfer regimen can limit the application of IMERs in HPLC. Infact when microparticulate supports are employed, the system operates under diffusionlimiting conditions because the substrate reaches the catalytic sites more slowly than the rate of enzymatic product formation [8].…”
Section: Introductionmentioning
confidence: 99%
“…Many suitable reaction techniques have been published for this purpose [641][642][643][644][645][646][647][648][649][650]. The derivative reaction is performed after the separation of the sample by the column and prior to detection in a continuous reactor.…”
Section: Reaction Detectorsmentioning
confidence: 99%
“…Some typical reaction detector configurations are shown in Figure 8.38. For reactions using solid-phase reagents, immobilized enzymes, etc., a packed bed tubular reactor is used [646,647,650,654]. With segmented flow systems, that generally operate at low pressures, peristaltic pumps are commonly used.…”
Section: Reaction Detectorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ένας τρόπος αντιμετώπισης του παραπάνω προβλήματος είναι η "επισήμανση" της προσδιοριζόμενης ουσίας πριν ή μετά τη διαβίβαση από τη στήλη διαχωρισμού. Οι αντιδραστήρες ακινητοποιημένου ενζύμου επιτρέπουν μία τέτοια "επισήμανση", με μετατροπή της μη ανιχνεύσιμης προσδιοριζόμενης ένωσης, μέσω μίας ενζυμικής αντίδρασης, σε μία ένωση που μπορεί να δώσει χαρακτηριστικό αναλυτικό σήμα [59,60]. Εφαρμογές του συνδυασμού αντιδραστήρα ακινητοποιημένου ενζύμου-HPLC έχουν γίνει για την ανάλυση στεροειδών, αμινοξέων, ή σακχάρων, χαρακτηριστικά παραδείγματα των οποίων δίδονται στον Πίνακα 2.3.…”
Section: εφαρμογές ακινητοποιημένων ενζύμων στη χρωματογραφίαunclassified