Impact of four kVp combinations available in a dual‐source CT on the spectral performance of abdominal imaging: A task‐based image quality assessment on phantom data

Abstract: To compare the spectral performance of four combinations of kVp available in a third generation dual-source CT (DSCT) on abdominal imaging. Methods: An image-quality phantom was scanned with a DSCT using four kVp pairs (tube "A" voltage/tube "B" voltage): 100/Sn150 kVp, 90/Sn150 kVp, 80/Sn150 kVp, and 70/Sn150 kVp, classic parameters and dose level for abdomen examination (CTDI vol : 11 mGy). The noise power spectrum (NPS) and the task-based transfer function (TTF) of two inserts were computed on virtual monoc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 34 publications
0
13
1
Order By: Relevance
“…24 In this case, a conditioning of the ESF was performed using imQuest software to improve the TTF calculation and the TTF was often overestimated especially at low keV (40, 50, and 60 keV). 11,29,31 In addition, variations in TTFs may also be related to the composition of the inserts which move away from the clinical lesions and may therefore impact the Photoelectric/Compton discrimination for reconstructing VMI. To avoid these issues, in the present study we used higher contrast inserts containing iodine and calculated the TTF on 200 images from 10 acquisitions.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…24 In this case, a conditioning of the ESF was performed using imQuest software to improve the TTF calculation and the TTF was often overestimated especially at low keV (40, 50, and 60 keV). 11,29,31 In addition, variations in TTFs may also be related to the composition of the inserts which move away from the clinical lesions and may therefore impact the Photoelectric/Compton discrimination for reconstructing VMI. To avoid these issues, in the present study we used higher contrast inserts containing iodine and calculated the TTF on 200 images from 10 acquisitions.…”
Section: Discussionmentioning
confidence: 99%
“…The low keV noise conditions and the low contrast of these inserts led to a relatively low CNR (CNR < 15) 24 . In this case, a conditioning of the ESF was performed using imQuest software to improve the TTF calculation and the TTF was often overestimated especially at low keV (40, 50, and 60 keV) 11,29,31 . In addition, variations in TTFs may also be related to the composition of the inserts which move away from the clinical lesions and may therefore impact the Photoelectric/Compton discrimination for reconstructing VMI.…”
Section: Discussionmentioning
confidence: 99%
“…A task‐based image quality assessment was performed using the iQMetrix‐CT software developed by a working group from the French Society of Medical Physicists. No articles or reports have yet been published to describe the iQMetrix‐CT software; however, this software has been used in various studies 11,12,30 …”
Section: Methodsmentioning
confidence: 99%
“…No articles or reports have yet been published to describe the iQMetrix-CT software; however, this software has been used in various studies. 11,12,30…”
Section: Task-based Image Quality Assessment-acr Geometric Phantommentioning
confidence: 99%
See 1 more Smart Citation