Biosensors for Medical Applications 2012
DOI: 10.1533/9780857097187.1.103
|View full text |Cite
|
Sign up to set email alerts
|

Impedance interrogated affinity biosensors for medical applications: novel targets and mechanistic studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 118 publications
0
8
0
Order By: Relevance
“…Then, the IME sensor was functionalised with an anti-BDNF antibody (SC-546, Santa Cruz Biotechnology) by immobilization of the antibody on the aldehyde group of the modified substrate 14 19 (see Experimental Procedures). When then samples were loaded, increases in the impedance of receptor-functionalized IMEs (impedance sensors) corresponded to the amount of the bound target molecule 20 , in this case, BDNF. The actual changes in impedance (ΔZ) were measured using an electrochemical impedance spectrometer (PGSTAT302N, Metrohm Autolab or IME analyzer, Cantis Incorporation) connected to the IME chip by two metal electrodes ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Then, the IME sensor was functionalised with an anti-BDNF antibody (SC-546, Santa Cruz Biotechnology) by immobilization of the antibody on the aldehyde group of the modified substrate 14 19 (see Experimental Procedures). When then samples were loaded, increases in the impedance of receptor-functionalized IMEs (impedance sensors) corresponded to the amount of the bound target molecule 20 , in this case, BDNF. The actual changes in impedance (ΔZ) were measured using an electrochemical impedance spectrometer (PGSTAT302N, Metrohm Autolab or IME analyzer, Cantis Incorporation) connected to the IME chip by two metal electrodes ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Thus, as a label free detection, the EIS biosensors enable direct determination of biomolecular recognition actions [ 27 ]. EIS biosensors are increased significantly due to their facile manipulation, rapid response, miniaturization capability, and readiness for lab-on-a-chip integration with low cost and online measurement to detect very low concentrations [ 28 , 29 ].…”
Section: Impedimetric Biosensorsmentioning
confidence: 99%
“…Biosensors overcome many limitations suffered by conventional analytical procedures which may be time consuming, are complex and need costly equipment [ 19 , 20 , 21 , 22 , 23 ]. Optical biosensors are considered as good alternatives to conventional analytical techniques to provide rapid, highly sensitive and real-time measurements [ 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%