2021
DOI: 10.1016/j.compbiomed.2020.104105
|View full text |Cite
|
Sign up to set email alerts
|

Implementation method for magneto-acoustic concentration tomography with magnetic induction (MACT-MI) based on the method of moments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…To further analyze the quality of the MNPs concentration images reconstructed by the three models, the correlation coefficient (CC) and relative error (RE) [19] were introduced to study the effects of different positions, concentrations and sizes of MNPs clusters on the reconstruction results. Based on the concentration reconstruction target, the CC and RE of the concentration reconstruction image were calculated according to formulas ( 16) and ( 17) where N m is the concentration value of the concentration reconstruction target; N m,r is the concentration value of the concentration reconstruction result; N is the average concentration value of the concentration reconstruction target; and N r is the average concentration value of the concentration reconstruction result.…”
Section: Numerical Research On Concentration Image Reconstructionmentioning
confidence: 99%
“…To further analyze the quality of the MNPs concentration images reconstructed by the three models, the correlation coefficient (CC) and relative error (RE) [19] were introduced to study the effects of different positions, concentrations and sizes of MNPs clusters on the reconstruction results. Based on the concentration reconstruction target, the CC and RE of the concentration reconstruction image were calculated according to formulas ( 16) and ( 17) where N m is the concentration value of the concentration reconstruction target; N m,r is the concentration value of the concentration reconstruction result; N is the average concentration value of the concentration reconstruction target; and N r is the average concentration value of the concentration reconstruction result.…”
Section: Numerical Research On Concentration Image Reconstructionmentioning
confidence: 99%
“…Magnetic nanoparticle imaging (MPI) is based on the magnetization of the MNPs by alternating excitation magnetic fields, and is able to provide an image with some degree of correlation with the spatial concentration distribution of the MNPs by measuring the magnetic intensity signals due to the variation of the magnetic flux. [11] Thus, the MPI method can generate a real-time image of MNP distribution for therapy and overcome the difficulty of accurately predicting MNP concentration distribution inside tumor region. [12,13] However, there are still some gaps in MPI technology that must be filled before it can be fully considered in a magnetic hyperthermia treatment.…”
Section: Introductionmentioning
confidence: 99%
“…In 2020, Shi et al proposed a magnetoacoustic concentration tomography of magnetically induced magnetic nanoparticles (MACT-MI), which proved that this method could detect and reconstruct the concentration of magnetic nanoparticles in biological tissues [10]. In the same year, Yan et al proposed a reconstruction algorithm of the MACT-MI inverse problem based on the method of moments, which used different shape models to reconstruct the image of the sound source and the concentration of superparamagnetic nanoparticles [11].…”
Section: Introductionmentioning
confidence: 99%