2024
DOI: 10.24084/repqj08.383
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of a New Method for an Improved Voltage Dips Evaluation by the Italian Power Quality Monitoring System in Presence of VT Saturation Effects

Abstract: The paper deals with a recent measurement improvement introduced into the Italian power quality monitoring system, concerning voltage dips detection and their proper evaluation in the presence of voltage transformer VT saturation phenomena. Saturation effects, essentially on network operated with isolated neutral, can give origin to "false" voltage dips, which can affect the on-line voltage monitoring during a few specific events (i.e. single line-to-ground faults). The "false dip" problem, on the other hand, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…• QuEEN validity criterion 1 outcome: a field that identifies the outcome of the algorithm based on the 2 nd harmonic evaluation, implemented in the MUs firmware [6], [7],…”
Section: A Interaction With Queen Databasementioning
confidence: 99%
See 1 more Smart Citation
“…• QuEEN validity criterion 1 outcome: a field that identifies the outcome of the algorithm based on the 2 nd harmonic evaluation, implemented in the MUs firmware [6], [7],…”
Section: A Interaction With Queen Databasementioning
confidence: 99%
“…In order to handle this problem a criterion, based on the detection of the 2 nd harmonic component has been implemented in QuEEN. The criterion, developed by RSE in cooperation with the Politecnico di Torino [6], [7] is able to identify "false" voltage dips with a global performance of 87%. Indeed, the 2 nd harmonic criterion has not a Boolean answer, as in some undefined cases as very short false voltage dips or multistage events, it is not able to identify the event type (true or false).…”
Section: Introductionmentioning
confidence: 99%
“…To properly identify those events and remove them from statistics, a criterion has been implemented in each MU. The algorithm, developed in cooperation with the Politecnico di Torino [25], is based on the detection of a second harmonic component in the measured voltages: the measurement is performed over 20 ms and refreshed every 10 ms. Then the following conditions are independently checked on all three phases:  the occurrence of a threshold overcoming for the 2nd harmonic level (fixed to a given percent of the rms value)  the succession of a minimum number of consecutive exceedances of the 2nd harmonic threshold. Energies 2021, 14, x FOR PEER REVIEW 5 of 26 employed measuring system in the PSs is characterized by the installation of phase-toground inductive VTs.…”
Section: Validity Criterion Based On 2nd Harmonicmentioning
confidence: 99%
“…To properly identify those events and remove them from statistics, a criterion has been implemented in each MU. The algorithm, developed in cooperation with the Politecnico di Torino [25], is based on the detection of a second harmonic component in the measured voltages: the measurement is performed over 20 ms and refreshed every 10 ms. Then the following conditions are independently checked on all three phases:…”
Section: Validity Criterion Based On 2nd Harmonicmentioning
confidence: 99%
See 1 more Smart Citation