2004
DOI: 10.1016/j.bbrc.2004.06.085
|View full text |Cite
|
Sign up to set email alerts
|

Implication of the differential roles of metallothionein 1 and 2 isoforms in the liver of rats as determined by polyacrylamide-coated capillary zone electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0

Year Published

2006
2006
2010
2010

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 22 publications
(25 citation statements)
references
References 37 publications
0
25
0
Order By: Relevance
“…Linear polyacrylamide has been used to eliminate EOF in both fused-silica capillary [74][75][76] and channels in PDMS microchips [77]. Stability of the polyacrylamide coating was enhanced by cross-linking [78].…”
Section: Static Wall Coatingmentioning
confidence: 99%
See 1 more Smart Citation
“…Linear polyacrylamide has been used to eliminate EOF in both fused-silica capillary [74][75][76] and channels in PDMS microchips [77]. Stability of the polyacrylamide coating was enhanced by cross-linking [78].…”
Section: Static Wall Coatingmentioning
confidence: 99%
“…CZE was used to analyze protein isoforms including a 1 -antitrypsin (Fig. 4) [168], metallothionein isoforms in rat liver [76] and in Synecho- Figure 4. Four replicate CZE separations of six major a 1 -antitrypsin isoforms.…”
Section: Other Proteinsmentioning
confidence: 99%
“…37,38) On the contrary, induction of MT-2 was reportedly greater than that of MT-1 in the liver of Zn-treated mice or tumor cells, 39) and Cu containing MT-2 induction was enhanced to a greater extent than that of MT-1 in the liver of LEC rats with the development of hepatitis. 24) In addition, commercially available MT-1 and MT-2 standards were observed to contain sub-isoforms. 40) Human hepatic MT isoforms in the tumor and juxta-tumor portion were distinctly separated into two isomers, MT-1 and MT-2, by capillary zone electrophoresis (Fig.…”
Section: Diagnostic Analysis Of Human and Lec Rat Hepaticmentioning
confidence: 99%
“…24) In order to suppress the protein adsorption and restrict the reversal of osmotic flow, the inner wall of the fused-silica capillary tube was coated with polyacrylamide by the method of Minami et al [28][29][30][31] The instrument conditions were as follows: the running buffer, 50 mM HEPES-Tris buffer (pH 7.4); samples, loaded onto the column for 7 s at a pressure of 50 mbar; the inlet of the capillary, anode; voltage, Ϫ25 kV; temperature, 26°C; detection, 214 and 254 nm. Samples were ultrafiltrated at molecular weight 50000 before running.…”
Section: Determination Of Metal Concentrationsmentioning
confidence: 99%
See 1 more Smart Citation