Important methods measurements to exam the accuracy and reliability of reflector-less total station measurements

Abstract: Inaccessible points are difficult to measure because the prism cannot be position in these points, so reflector-less total station has solved this problem and these points can be measured easily. But the vital question is, if these measurements are accurate and reliable. This research has carried out to identify the vital methods measurements that have to be done to identify the reliability and the exact accuracy of the reflector-less measurements. Results are not general for all total station types because ea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…A theodolite measures the angles in two directions by reading two circle scales, the horizontal circular scale, and the vertical circular scale. The electronic distance meter (EDM) measures the distances by using the laser that reflects the pack from the prism or from the target itself [30]- [32]. In this method total station must be located at a place where all the objects required to be measured are visible.…”
Section: Total Station Methodsmentioning
confidence: 99%
“…A theodolite measures the angles in two directions by reading two circle scales, the horizontal circular scale, and the vertical circular scale. The electronic distance meter (EDM) measures the distances by using the laser that reflects the pack from the prism or from the target itself [30]- [32]. In this method total station must be located at a place where all the objects required to be measured are visible.…”
Section: Total Station Methodsmentioning
confidence: 99%
“…Although TS is able to measure a large area according to S.I. Mohammed [30], it prolongs the measurement time of collecting the data according to V. Č. Aksamitauskas et al [31] and thus increases manpower, increasing the measurement cost according to Zulkipli et al [32]; however, T.B. Afeni and F.T.…”
Section: Comparison Between Total Station (Ts) Airborne Lidar and Unmanned Aerial Vehicle (Uav)mentioning
confidence: 99%
“…The first group consist of technical parameters of the instrument, the stability of the support etc. The properties of the measurement path include the distance of measurement and atmospheric conditions [7,8]. The last component is the target.…”
Section: Introductionmentioning