2013
DOI: 10.1063/1.4776715
|View full text |Cite
|
Sign up to set email alerts
|

Improved accuracy thin film permeability extraction for a microstrip permeameter

Abstract: It is shown using full-wave simulations that several of the conventional assumptions made for extracting permeability data from a microstrip permeameter are not justified. In particular, the proportionality between the measured effective permeability in the device and the true permeability of the film is not a constant. It is a function of the permeability of the film, its geometry and the dimensions of the microstrip permeameter. A model exploiting the analyticity of the function relating effective to true pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…[156][157][158][159][160][161][162][163][164] In order to obtain the permeability spectrum of thin film (PSTF), it was suggested that a wideband measurement can reveal the frequency dependence of permeability. [165][166][167][168][169][170][171] After that, the measurement of the PSTF has been developed both in design [172,173] and in static magnetic field modulation. [174,175] More recently, the electric detection of FMR based on the spin rectification effect (SRE) was suggested, by which the dynamics of magnetization has been observed even at large cone angle.…”
Section: Experimental Methods Of the Mdcpmentioning
confidence: 99%
See 1 more Smart Citation
“…[156][157][158][159][160][161][162][163][164] In order to obtain the permeability spectrum of thin film (PSTF), it was suggested that a wideband measurement can reveal the frequency dependence of permeability. [165][166][167][168][169][170][171] After that, the measurement of the PSTF has been developed both in design [172,173] and in static magnetic field modulation. [174,175] More recently, the electric detection of FMR based on the spin rectification effect (SRE) was suggested, by which the dynamics of magnetization has been observed even at large cone angle.…”
Section: Experimental Methods Of the Mdcpmentioning
confidence: 99%
“…Recently, Sebastian develop an improved-accuracy thin film permeability extraction for a microstrip permeameter, in which the following issues faced in the conventional permeability extraction methods are overcome: [173] (i) the need of a known reference sample, (ii) the need for an external dc magnetic field biasing/saturation source, (iii) a priori knowledge of saturation magnetization M s and anisotropy field H K , which are extremely difficult and error-prone to measure, (iv) the use of brute force complex optimization or simplified conformal mapping techniques. It is shown using full-wave simulations that several of the conventional assumptions made for extracting permeability data from a microstrip permeameter are not justified.…”
Section: Pstf Modulated By Static Fieldmentioning
confidence: 99%
“…The real l 0 and imaginary l 00 permeabilities were measured as a function of frequency using a vector network analyzer with a customized microstrip permeameter. 8 For cross-section TEM and off-axis electron holography characterization, samples were prepared using cutting, mechanical polishing, followed by dimpling to create thin areas with total thicknesses of about 10 lm. Samples in the plan-view geometry were also prepared, with dimpling and ion-milling done only from the back side of the wafer.…”
Section: Methodsmentioning
confidence: 99%