Improved measurement characteristics in collimation testing using Lau interferometry and Fourier fringe analysis technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…More recently, Chang in [27] proposes a collimation testing and calibration using a heterodyne Moir method. This method is fast, relatively simple and achieves a positioning accuracy close to m 7 m. On the other hand, the technique proposed by Disawal is based on Lau effect and achieves collimation of incoherent beams with an accuracy of m 1 m [28]. Talbot interferometry is used suitably modified by Patorsky to prevent the continued displacement of the second grating.…”
Section: Resultsmentioning
confidence: 99%
“…More recently, Chang in [27] proposes a collimation testing and calibration using a heterodyne Moir method. This method is fast, relatively simple and achieves a positioning accuracy close to m 7 m. On the other hand, the technique proposed by Disawal is based on Lau effect and achieves collimation of incoherent beams with an accuracy of m 1 m [28]. Talbot interferometry is used suitably modified by Patorsky to prevent the continued displacement of the second grating.…”
Section: Resultsmentioning
confidence: 99%
“…Most of them are based on interferometry [1][2][3][4][5] or on self-imaging techniques [6][7][8][9]. In addition, several techniques have been proposed in the last years [10][11][12][13][14][15]. In particular, several collimation methods based on self-imaging that do not need a lateral displacement of the grating have been proposed, being these devices simple an stable.…”
Section: Q3mentioning
confidence: 99%
“…Errors in beam collimation may result in severe degradation of system performance. Automated interferogramanalysis-based techniques have been incorporated to improve the measurement characteristics [17][18][19][20][21]. The use of these techniques has increased the performance of the collimation test substantially.…”
Section: Applicationmentioning
confidence: 99%
“…They claimed the value of Δf to be 7 μm. Recently, we reported collimation testing [20] in Lau interferometry using Fourier-fringe analysis with a reported resolution of 1 μm. By using the present technique, the resolution in measurement, Δf , was found to be 10 μm for the collimating lens with 250 mm focal length and 50 mm diameter.…”
Section: Applicationmentioning
confidence: 99%