1997
DOI: 10.1002/(sici)1097-0231(19970131)11:2<209::aid-rcm734>3.0.co;2-e
|View full text |Cite
|
Sign up to set email alerts
|

Improved Reproducibility and Increased Signal Intensity in Matrix-assisted Laser Desorption/Ionization as a Result of Electrospray Sample Preparation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

3
91
0

Year Published

1999
1999
2012
2012

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 127 publications
(94 citation statements)
references
References 13 publications
3
91
0
Order By: Relevance
“…The peptides of the combined calibration mixtures 1 and 2 were dissolved in 20% ACN/0.01% TFA to final concentrations of 125 fmol/ L des-arg 1 -bradykinin, 413 fmol/ L angiotensin I, 163 fmol/ L glu 1 -fibrinopeptide B, 6 fmol/ L neurotensin, 250 fmol/ L ACTH (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17), 188 fmol/ L ACTH (18 -39), 375 fmol/ L ACTH , and 438 fmol/ L bovine insulin. The in-solution BSA digest was dissolved in 30% ACN/0.1% TFA to a final concentration of 1 fmol/ L. p-Methoxybenzylpyridinium chloride, which was used for the measurements of the effective temperatures, was dissolved in 20% ACN to final concentrations of 2 and 4 pmol/ L. The initial velocities were measured from 350 fmol bovine insulin as analyte (c ϭ 700 fmol/ L, V ϭ 0.5 L) dissolved in 20% ACN/0.01% TFA; 0.5 L matrix solution (30% ACN/0.1% TFA, c ϭ 45 mM for SA; 70% ACN/0.1% TFA, c ϭ 30 mM for all other matrices) and 0.5 L analyte solution were mixed directly on a polished steel target and air-dried for standard DD preparation.…”
Section: Sample Preparation and Measurementmentioning
confidence: 99%
“…The peptides of the combined calibration mixtures 1 and 2 were dissolved in 20% ACN/0.01% TFA to final concentrations of 125 fmol/ L des-arg 1 -bradykinin, 413 fmol/ L angiotensin I, 163 fmol/ L glu 1 -fibrinopeptide B, 6 fmol/ L neurotensin, 250 fmol/ L ACTH (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17), 188 fmol/ L ACTH (18 -39), 375 fmol/ L ACTH , and 438 fmol/ L bovine insulin. The in-solution BSA digest was dissolved in 30% ACN/0.1% TFA to a final concentration of 1 fmol/ L. p-Methoxybenzylpyridinium chloride, which was used for the measurements of the effective temperatures, was dissolved in 20% ACN to final concentrations of 2 and 4 pmol/ L. The initial velocities were measured from 350 fmol bovine insulin as analyte (c ϭ 700 fmol/ L, V ϭ 0.5 L) dissolved in 20% ACN/0.01% TFA; 0.5 L matrix solution (30% ACN/0.1% TFA, c ϭ 45 mM for SA; 70% ACN/0.1% TFA, c ϭ 30 mM for all other matrices) and 0.5 L analyte solution were mixed directly on a polished steel target and air-dried for standard DD preparation.…”
Section: Sample Preparation and Measurementmentioning
confidence: 99%
“…The homogeneity over a large surface area of the sample is a major concern regarding reproducibility in MALDI [23]. To prevent unwanted effects caused by inconsistencies of the target preparation, all MALDI targets were routinely prepared in the following way.…”
Section: Target Preparationmentioning
confidence: 99%
“…The method selected here to prepare homogenous samples of variable thickness is electrospray (ES) deposition of analyte/matrix solution [11,12]. Electrospray produces more uniform, fine-grained sample spots than the more convenient and widespread dried droplet technique, which tends to form large matrix crystals in random locations.…”
mentioning