Improved ROCOF relay for islanding detection of solar distributed generation

Abstract: <p>In recent years to meet the energy consumption demand of the world, all are working on renewable distributed generation (RDG) due to shortage of fossil fuels. The RDG systems after integrating with grid, has a disadvantage of islanding in the power system. Islanding is caused, if the RDG is supplying power to load connected due to failures in the grid. As per IEEE 1547 distributed generation (DG) interconnection standards, the islanding should be detected within 2 seconds after islanding. In this pape… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 24 publications
0
1
0
Order By: Relevance
“…Passive method identifies islanding by monitoring the parameters such as frequency, voltage, current, active power, reactive power and harmonic distortion. Many techniques were subsequently introduced with various combination of parameters and settings such as rate of change of positive and negative sequence component [4], rate of change of frequency (ROCOF) [5], rate of change of output power [6], rate of change of voltage and changes in power factors [7], voltage unbalance and total harmonic distortion of current [8] and combinations of four passive parameters [9]. The very recent research considered load angle and mechanical power parameters [10], undervoltage block function [11] and sensitivity of different passive parameters [12].…”
Section: Introductionmentioning
confidence: 99%
“…Passive method identifies islanding by monitoring the parameters such as frequency, voltage, current, active power, reactive power and harmonic distortion. Many techniques were subsequently introduced with various combination of parameters and settings such as rate of change of positive and negative sequence component [4], rate of change of frequency (ROCOF) [5], rate of change of output power [6], rate of change of voltage and changes in power factors [7], voltage unbalance and total harmonic distortion of current [8] and combinations of four passive parameters [9]. The very recent research considered load angle and mechanical power parameters [10], undervoltage block function [11] and sensitivity of different passive parameters [12].…”
Section: Introductionmentioning
confidence: 99%