2021
DOI: 10.1101/2021.10.05.463265
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Improved Ultrasound Localization Microscopy based on Microbubble Uncoupling via Transmit Excitation (MUTE)

Abstract: Ultrasound localization microscopy (ULM) demonstrates great potential for visualization of tissue microvasculature at depth with high spatial resolution. The success of ULM heavily depends on the robust localization of isolated microbubbles (MBs), which can be challenging in vivo especially within larger vessels where MBs can overlap and cluster close together. While MB dilution alleviates the issue of MB overlap to a certain extent, it drastically increases the data acquisition time needed for MBs to populate… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0
1

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 30 publications
0
1
0
1
Order By: Relevance
“…The precision of this localization is a critical step in obtaining super-resolution 5 . Instead of merely superposing each of the microbubble localizations, as done in super-resolution microscopy, the movements of the microbubbles as they follow the bloodstream between frames are used to create trajectories that can reveal microbubble velocity and direction 6 7 8 9 10 . Lastly, another essential difference between super-resolved microscopy and ultrasound is motion.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The precision of this localization is a critical step in obtaining super-resolution 5 . Instead of merely superposing each of the microbubble localizations, as done in super-resolution microscopy, the movements of the microbubbles as they follow the bloodstream between frames are used to create trajectories that can reveal microbubble velocity and direction 6 7 8 9 10 . Lastly, another essential difference between super-resolved microscopy and ultrasound is motion.…”
mentioning
confidence: 99%
“…Die Präzision dieser Lokalisierung ist ein entscheidender Schritt zur Erzielung der Superresolution 5 . Anstatt wie bei der Superresolution-Mikroskopie jede einzelne Lokalisierung der Mikrobläschen zu überlagern, werden die Bewegungen der Mikrobläschen, während sie zwischen den Bildern dem Blutstrom folgen, verwendet, um Trajektorien zu erstellen, die die Geschwindigkeit und Richtung der Mikrobläschen aufzeigen können 6 7 8 9 10 . Schließlich ist die Bewegung ein weiterer wesentlicher Unterschied zwischen der Superresolution-Mikroskopie und dem -Ultraschall.…”
unclassified