Improved volumetric imaging for DCE-MRI using parallel imaging and dynamic compressed sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…Similar to DSC-MRI, image acceleration is often used in DCE-MRI to improve spatial and/or temporal resolution. For example, dynamic compressed sensing can be combined with parallel imaging (GRAPPA) and either 3D or 2D+SMS encoding schemes for DCE-MRI, resulting in improved noise characteristics and higher spatiotemporal resolution (Yoon et al, 2014). Another promising method is the golden-angle radial sparse parallel (GRASP) scheme, which employs radial k-space encoding with golden angle ordering to achieve high spatial resolution and flexible post-hoc temporal resolution as high as 2.5 s (Rossi Espagnet et al, 2015).…”
Section: Pulse Sequences: T 1 Mapping and Dynamic Data Acquisition-mentioning
confidence: 99%
See 1 more Smart Citation
“…Similar to DSC-MRI, image acceleration is often used in DCE-MRI to improve spatial and/or temporal resolution. For example, dynamic compressed sensing can be combined with parallel imaging (GRAPPA) and either 3D or 2D+SMS encoding schemes for DCE-MRI, resulting in improved noise characteristics and higher spatiotemporal resolution (Yoon et al, 2014). Another promising method is the golden-angle radial sparse parallel (GRASP) scheme, which employs radial k-space encoding with golden angle ordering to achieve high spatial resolution and flexible post-hoc temporal resolution as high as 2.5 s (Rossi Espagnet et al, 2015).…”
Section: Pulse Sequences: T 1 Mapping and Dynamic Data Acquisition-mentioning
confidence: 99%
“…Quarles et al Page 63 Table 1 Recent advances in DSC-and DCE-MRI acquisition methods Jochimsen et al, 2007;Newbould et al, 2007GRASP Rossi Espagnet et al, 2015PRESTO Gelderen et al, 2000Pedersen et al, 2004 Dual-temporal resolution Jelescu et al, 2011SPICE Paulson et al, 2016 Multi-echo SAGE (Schmiedeskamp et al, 2013(Schmiedeskamp et al, , 2012Skinner et al, 2014;Stokes et al, 2014) Dual-echo Ewing and Bagher-Ebadian, 2013 sSAGE Stokes et al, 2016b;Stokes and Quarles, 2016SPICE Paulson et al, 2016Acceleration Partial Fourier d'Arcy et al, 2002Jonathan et al, 2013Oesterle et al, 2000 Compressed sensing Yoon et al, 2014;Smith et al, 2012SMS Eichner et al, 2014…”
Section: Prestomentioning