2006
DOI: 10.1080/17453670610046479
|View full text |Cite
|
Sign up to set email alerts
|

Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation

Abstract: BackgroundSuggestions for improved wear performance of total knee replacements have included replacement of standard CoCr femoral components with ceramic and replacement of 3.5-Mrad ultra-high molecular weight polyethylene (UHMWPE) inserts with 5-or 7-Mrad UHMWPE inserts. The ceramic materials used clinically have included alumina, zirconia ceramic and oxidized zirconium.Patients and method We compared both CoCr and zirconia versions of the Bi-Surface knee replacement in a 6-station knee simulator using alpha … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
45
0
4

Year Published

2007
2007
2024
2024

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 65 publications
(53 citation statements)
references
References 18 publications
4
45
0
4
Order By: Relevance
“…However, the effect of increased laxity on implant wear is unknown. Furthermore, most wear studies to date have not sufficiently simulated the ligaments (D'Lima et al, 2001;Laurent et al, 2003;Tsukamoto et al, 2006). At best, mechanical springs were used to replicate the ligaments (Benson et al, 2001;Schwenke et al, 2005;Walker et al, 1997).…”
Section: Introductionmentioning
confidence: 99%
“…However, the effect of increased laxity on implant wear is unknown. Furthermore, most wear studies to date have not sufficiently simulated the ligaments (D'Lima et al, 2001;Laurent et al, 2003;Tsukamoto et al, 2006). At best, mechanical springs were used to replicate the ligaments (Benson et al, 2001;Schwenke et al, 2005;Walker et al, 1997).…”
Section: Introductionmentioning
confidence: 99%
“…Decades of wide spread and increasing use of Zr compounds in medical practice have so far not been associated with clear evidence for Zr toxicities. Examples for successful medical applications include Zr-containing deodorant sticks, aerosol antiperspirants and poison-oak lotions [53], as well as life-long, internal placement of Zr-containing implants in dental restorative practice [54], in total knee [55] and hip [56] replacement, and in middle-ear ossicular chain reconstruction surgery [57]. Sorbent hemodialysis, using Zr-based hemodialysate regenerating cartridges, has been in use for the treatment of acute renal failure and end-stage renal failure patients since 1973 [20].…”
Section: And Solutionsmentioning
confidence: 99%
“…These findings may be prompting health care providers to appreciate that the real value of MIS can be realized only when the surgical accuracy, safety, and high reliability are not compromised. While total hip arthroplasty has a long history of ceramic prosthesis, TKA has not been considered good for the application of ceramic components due to the concern over their mechanical properties [12,13,19,26]. Recently a great deal of attention has been paid to the ceramic femoral component which is claimed to be advantageous over traditional cobalt-chrome component in longevity [12,13,19,27].…”
Section: Additional Skin Incision-1 (2%)mentioning
confidence: 99%