Improvement of High-Throughput Experimentation Using Synthesis Robots by the Implementation of Tailor-Made Sensors

Abstract: A small, low-cost, self-produced photometer is implemented into a synthesis robot and combined with a modified UV chamber to enable automated sampling and online characterization. In order to show the usability of the new approach, two different reversible addition–fragmentation chain transfer (RAFT) polymers were irradiated with UV light. Automated sampling and subsequent characterization revealed different reaction kinetics depending on polymer type. Thus, a long initiation time (20 min) is required for the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…2a). THF as standard solvent for polymer purification using dialysis 28 results in the fastest purification velocity for every monomer ( D1–D12 ), whereas toluene shows a significantly slower velocity ( D13–D24 ). In chloroform, there is no visible diffusion through the membrane ( D25–D27 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…2a). THF as standard solvent for polymer purification using dialysis 28 results in the fastest purification velocity for every monomer ( D1–D12 ), whereas toluene shows a significantly slower velocity ( D13–D24 ). In chloroform, there is no visible diffusion through the membrane ( D25–D27 ).…”
Section: Resultsmentioning
confidence: 99%
“…† Moreover, we investigated the influence of the molar mass cut-off of the dialysis tubing, utilizing two different dialysis tubings based on regenerated cellulose with a cut-off of 1 kDa and 8 kDa, respectively. Finally, the effect of three different solvents on the dialysis process was investigated: THF as a polar standard solvent in polymer purification utilizing dialysis, 28 toluene as a non-polar solvent, and chloroform as a halogenated solvent.…”
Section: Resultsmentioning
confidence: 99%
“…The RAFT-polymerization was performed in analogy to an established procedure in the Schubert-group. 72 Each small scale reaction was performed in a similar manner. All utilized amounts of the educts (Monomer: Sty, MMA.…”
Section: Methodsmentioning
confidence: 99%
“…[329][330][331] Meanwhile, some studies have integrated characterization methods to achieve online characterization. [332] Furthermore, flow-based chemical systems have been also widely applied in soft matter system. [333,334] Their unique characteristic is their ability to enable reactions at smaller scales, thus reducing potential risks.…”
Section: Autonomous Experimentationmentioning
confidence: 99%