Abstract:Temperature control is an important factor which influences the accuracy of
refrigerant heat transfer experimental results. In this paper, the three
temperature control methods for the electric heating water tank (EHWT) in the
single tube heat transfer experimental rig are investigated. The error of PID
controller is ? 1?C and the stability time is 390s. The control performance is
not satisfactory. A fuzzy controller and a fuzzy PID controller are designed
to improve temperature control perfo… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.