1996
DOI: 10.1016/0300-9572(96)83755-5
|View full text |Cite
|
Sign up to set email alerts
|

Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
45
0
5

Year Published

2002
2002
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(52 citation statements)
references
References 0 publications
2
45
0
5
Order By: Relevance
“…As such, using an ITV improved coronary perfusion pressure and myocardial blood flow in both standard (6) and ACD CPR in adult animal models (7). Furthermore, coronary perfusion pressure was significantly higher in patients receiving ACD CPR with the ITV when compared with ACD CPR alone (8).…”
mentioning
confidence: 95%
“…As such, using an ITV improved coronary perfusion pressure and myocardial blood flow in both standard (6) and ACD CPR in adult animal models (7). Furthermore, coronary perfusion pressure was significantly higher in patients receiving ACD CPR with the ITV when compared with ACD CPR alone (8).…”
mentioning
confidence: 95%
“…It is also a reasonable representation of open chest CPR with manual cardiac compression, which obviously works by a pure "cardiac pump" mechanism. A similar state of affairs can occur in children (and young pigs 46,47 ), who have small compliant chest walls.…”
Section: Modern Physiology Of Blood Flow During Cprmentioning
confidence: 79%
“…This approach is known as active compression-decompression CPR or ACD-CPR ( Figure 3). Today, active decompression of the chest during CPR can be accomplished using a specially designed plunger applied to the human sternum 46,[49][50][51] , which is sold commercially in Europe as the Ambu Cardiopump ® . Figure 4 illustrates the steady-state effect of active decompression of the chest to negative 20 mmHg, the maximum reported in the literature 50,52,53 .…”
Section: Modern Physiology Of Blood Flow During Cprmentioning
confidence: 99%
See 1 more Smart Citation
“…18 These results led to the testing of an impedance threshold device (ITD) called the ResQPod s (Zoll Medical Corp., Chelmsford, MA, USA) along with the ResQPump s (Zoll Medical Corp., Chelmsford, MA, USA), to augment the benefits of ACD CPR. 19 The ResQPod s (Zoll Medical Corp., Chelmsford, MA, USA) can attach to a facemask or endotracheal tube (Figure 2). An ITD is used during basic and advanced life support as part of the airway, preventing inspiration during the CPR decompression phase.…”
Section: Addition Of the Impedance Threshold Devicementioning
confidence: 99%