Improving beam simulations as well as machine and target protection in the SINQ beam line at PSI-HIPA

Abstract: With a nominal beam power of nearly 1.4 MW, the PSI High Intensity Proton Accelerator (HIPA) is currently at the forefront of the high intensity frontier of particle accelerators. Key issues of this facility are minimization of beam losses as well as safe operation of the SINQ spallation source. Particular attention is being recently paid towards an improved understanding of the properties of the SINQ beam line by both enhancing the beam transport simulations and developing new diagnostic elements which can al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…The HIPA at the Paul Scherrer Institut (PSI) is one of the most powerful proton cyclotron facilities in the world, with nearly 1.4 MW of beam power [20]. The HIPA Archiver is an in-house developed archiver software that stores values of EPICS [21] Process Variables, i.e., channels, according to tailored configuration settings [22].…”
Section: Dataset and Preprocessingmentioning
confidence: 99%
“…The HIPA at the Paul Scherrer Institut (PSI) is one of the most powerful proton cyclotron facilities in the world, with nearly 1.4 MW of beam power [20]. The HIPA Archiver is an in-house developed archiver software that stores values of EPICS [21] Process Variables, i.e., channels, according to tailored configuration settings [22].…”
Section: Dataset and Preprocessingmentioning
confidence: 99%
“…The HIPA at the Paul Scherrer Institut (PSI) is one of the most powerful proton cyclotron facilities in the world, with nearly 1.4 MW of beam power [20]. The HIPA Archiver is an in-house developed archiver software that stores values of EPICS [21] Process Variables, i.e.…”
Section: Dataset and Preprocessingmentioning
confidence: 99%
“…We applied the previously described model to data from the HIPA diagnostic devices. HIPA is one of the most powerful cyclotrons in the world, able to provide a 1.4 MW beam to several experiments [17]. To operate and monitor this facility, about 180,000 signals are generated by devices of very different nature, of which about 19,000 are stored in a database (the Archiver).…”
Section: Data Collection and Exploitationmentioning