2021
DOI: 10.1016/j.pep.2021.105845
|View full text |Cite
|
Sign up to set email alerts
|

Improving SDS-PAGE method for monoclonal antibodies: The advantages of Tris-Acetate over Tris-Glycine SDS-PAGE system and comparison with CE-SDS method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The higher voltage may cause an increase in heat and acceleration in the denaturation process. Better denaturation of proteins results in higher resolution, which can be the reason for a more broad range of molecular weight proteins when 110 V was applied than 80 V . According to these results, the H.…”
Section: Resultsmentioning
confidence: 89%
See 1 more Smart Citation
“…The higher voltage may cause an increase in heat and acceleration in the denaturation process. Better denaturation of proteins results in higher resolution, which can be the reason for a more broad range of molecular weight proteins when 110 V was applied than 80 V . According to these results, the H.…”
Section: Resultsmentioning
confidence: 89%
“…Better denaturation of proteins results in higher resolution, which can be the reason for a more broad range of molecular weight proteins when 110 V was applied than 80 V. 63 According to these results, the H. scoparia protein extracts were composed of nine protein bands with apparent molecular weights between approximately 135 and 17 kDa. In the study of Rouxel et al, 64 proteins of Palmaria palmata had six protein bands with apparent molecular weights between 59.6 and 15.2 kDa.…”
Section: 5mentioning
confidence: 92%
“…Moreover, proline content of the analyte also has critical impact on electrophoretic behavior which may result in a higher apparent MW [8]. Thus, the apparent molecular mass of proteins identified by SDS-PAGE may not be a true reflection of the mass of polypeptide chain [7,19]. As reported by Dong and Kang, advanced and automated versions of this approach, such as CE-SDS technology, could be employed as a promising alternative to obtain higher resolution and better precision about MW of complex proteins [20].…”
Section: Sds-pagementioning
confidence: 99%
“…Determination of MW of proteins after treating them with a strong anionic detergent, SDS, and separation based on migration distance in PAGE, is a well‐established method [7]. Since its introduction in 1969, this is still the widely used method because of its simplicity, rapidity, and inexpensive nature.…”
Section: Introductionmentioning