2018
DOI: 10.30802/aalas-jaalas-18-000017
|View full text |Cite
|
Sign up to set email alerts
|

Improving the Patency of Jugular Vein Catheters in Sprague–Dawley Rats by Using an Antiseptic Nitrocellulose Coating

Abstract: Preclinical studies in animals often require frequent blood sampling over prolonged periods. A preferred method in rats is the implantation of a polyurethane catheter into the jugular vein, with heparinized glycerol as a lock solution. However, analysis of various biologic compounds (for example, microRNA) precludes the use of heparin. We used sodium citrate as an alternative to heparin but observed more frequent loss of catheter patency. We hypothesized that this effect was due to evaporation of lock solution… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 23 publications
(34 reference statements)
0
6
0
Order By: Relevance
“…Thrombosis is a disease involving multiple factors and systems and a major contributor to global health burden [23]. Many approaches, such as changes in the diameter of catheter [24], tuning of catheter-to-vein ratio [25], novel catheter surface coatings [26], use of catheter-locking solutions [27] or anticoagulants [28], and handgrip exercise [29], have been investigated to prevent CRT. Numerous reports on CRT were clinical studies.…”
Section: Discussionmentioning
confidence: 99%
“…Thrombosis is a disease involving multiple factors and systems and a major contributor to global health burden [23]. Many approaches, such as changes in the diameter of catheter [24], tuning of catheter-to-vein ratio [25], novel catheter surface coatings [26], use of catheter-locking solutions [27] or anticoagulants [28], and handgrip exercise [29], have been investigated to prevent CRT. Numerous reports on CRT were clinical studies.…”
Section: Discussionmentioning
confidence: 99%
“…The catheters were tunneled subcutaneously and exteriorized at the base of the neck. 17 The animals were recovered for 7 days after surgery. Catheter patency was maintained with 50 units/mL heparin in 0.9% saline (Dai Han Pharm., Ansan, South Korea).…”
Section: Methodsmentioning
confidence: 99%
“…After a two week acclimation period, animals were subjected to surgery for placement of jugular vein catheters 12 . The animals were anesthetized using isoflurane inhalation (5% induction, 2–3% maintenance) and body weight was measured on a digital scale.…”
Section: Methodsmentioning
confidence: 99%
“…After a final check for patency, the catheter was flushed with 0.6 mL bacteriostatic saline and locked with 0.15 mL 4% sodium citrate (4B7867Q, Fenwal Inc., Lake Zurich, IL, USA). Liquid bandage (CVS Health, Woonsocket, RI, USA) was applied to the exteriorized catheter to extend patency 12 . After 2 d of surgical recovery, patency was verified by placing animals into a rodent restrainer (cat.…”
Section: Methodsmentioning
confidence: 99%