In-beam activation analysis facility at MLZ, Garching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
20
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 48 publications
(21 citation statements)
references
References 21 publications
1
20
0
Order By: Relevance
“…33 The beamline provides a collimated cold neutron beam with an area of 12.6 mm 2 and a flux of 1.35 × 10 9 cm −2 s −1 which can be reduced by different attenuators (5.9%, 16%, and 47%) to mitigate pile-up effects at count rates above 10 3 s −1 . 35 The 14 mm diameter SiG electrodes were placed in the NDP vacuum chamber with the coating facing the incoming beam at an angle of 45 • . The N4DP setup at the PGAA facility is described in more detail by Trunk et al 33 High-resolution cross-sectional SEM images.-The morphology of the SiG electrodes in their pristine state and after different numbers of cycles was investigated by high-resolution cross-sectional scanning electron microscopy (SEM).…”
Section: Methodsmentioning
confidence: 99%
“…33 The beamline provides a collimated cold neutron beam with an area of 12.6 mm 2 and a flux of 1.35 × 10 9 cm −2 s −1 which can be reduced by different attenuators (5.9%, 16%, and 47%) to mitigate pile-up effects at count rates above 10 3 s −1 . 35 The 14 mm diameter SiG electrodes were placed in the NDP vacuum chamber with the coating facing the incoming beam at an angle of 45 • . The N4DP setup at the PGAA facility is described in more detail by Trunk et al 33 High-resolution cross-sectional SEM images.-The morphology of the SiG electrodes in their pristine state and after different numbers of cycles was investigated by high-resolution cross-sectional scanning electron microscopy (SEM).…”
Section: Methodsmentioning
confidence: 99%
“…The three investigated Nb samples were prepared from the same single-crystal commercially obtained from MaTeck 25 . The concentration of impurities of the crystal has been measured by neutron activation and prompt gamma activation analysis 26 . Hydrogen, tungsten and tantalum have been tracked as main detectable impurities with a concentration between 200-350 ppm each 27 .…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The prompt gamma rays were detected with a high-purity germanium (HPGe) detector with a relative efficiency of 60% surrounded by a bismuth germanate scintillator annulus as a Compton suppressor. 33 The spectra were collected using an ORTEC Dspec-50 spectrometer. The gamma spectra were evaluated using the Hypermet-PC program, and the list of peak energies and areas were statistically analyzed, then fit to elemental data in the spectroscopy database, as described by Z. Révay.…”
Section: Methodsmentioning
confidence: 99%