2015 IEEE 42nd Photovoltaic Specialist Conference (PVSC) 2015
DOI: 10.1109/pvsc.2015.7355608
|View full text |Cite
|
Sign up to set email alerts
|

In-situ module-level I–V tracers for novel PV monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 2 publications
0
13
0
Order By: Relevance
“…Figure 14 shows I-V and P-V curves of the panel that has a hot spot and a panel without faults as a comparison. It is observed that the voltage of the panel with failure falls at around 16Vdc, showing a typical behavior of a damaged or "shaded" cell [14][15][16][17] which matches the thermography image. Reviewing the P-V curve of the panels, the decrease in the maximum power point (MPP) is observed, power decreases from 94.16W on the panel without anomalies (see Figure 14a), to 69.97W on the panel with anomalies (with a hotspot, see Figure 14b) obtaining a 25.69% less power in the panel with the hot spot compared to a panel without failures.…”
Section: I-v/p-v Curves Analysis As First Validationmentioning
confidence: 70%
“…Figure 14 shows I-V and P-V curves of the panel that has a hot spot and a panel without faults as a comparison. It is observed that the voltage of the panel with failure falls at around 16Vdc, showing a typical behavior of a damaged or "shaded" cell [14][15][16][17] which matches the thermography image. Reviewing the P-V curve of the panels, the decrease in the maximum power point (MPP) is observed, power decreases from 94.16W on the panel without anomalies (see Figure 14a), to 69.97W on the panel with anomalies (with a hotspot, see Figure 14b) obtaining a 25.69% less power in the panel with the hot spot compared to a panel without failures.…”
Section: I-v/p-v Curves Analysis As First Validationmentioning
confidence: 70%
“…Based on onsite IVCT data, several researchers have investigated diagnostic strategies [32]- [34]. IVCT is a fast and accurate way to check performance and troubleshoot issues before becoming significant [35]. Many simple characteristic parameters can be derived directly from I − V curves, such as opencircuit voltage (V oc ), short circuit current (I sc ), maximum current (I m ), and maximum voltage (V m ), as well as Fill Factor (FF) [36].…”
Section: Introductionmentioning
confidence: 99%
“…The device may be even more expensive if additional requirements are needed, such as working outdoors, using a wi-fi connection, or allowing specific electrical voltages and intensities. Some devices have been developed in an attempt to satisfy these demands at low cost [31]. The second option is probably the easiest to implement, due to the simplicity of the experimental configuration.…”
Section: Introductionmentioning
confidence: 99%