2006
DOI: 10.1177/1045389x06064889
|View full text |Cite
|
Sign up to set email alerts
|

In situ Strain and Temperature Monitoring of Adaptive Composite Materials

Abstract: An optical fiber sensor is designed to simultaneously measure strain and temperature in an adaptive composite material. The sensor is formed by splicing two fiber Bragg gratings (FBGs) close to each other, which are written in optical fibers with different core dopants and concentrations. Their temperature sensitivities are hence different. The sensor is tested on an adaptive composite laminate made of unidirectional Kevlar-epoxy prepreg plies. Several 150 mm diameter prestrained NiTiCu shape memory alloy (SMA… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(26 citation statements)
references
References 44 publications
0
25
0
1
Order By: Relevance
“…2. To reduce the error in the discrimination, a small conditional number is desired 9 . The number associated with Eq.…”
Section: Resultsmentioning
confidence: 99%
“…2. To reduce the error in the discrimination, a small conditional number is desired 9 . The number associated with Eq.…”
Section: Resultsmentioning
confidence: 99%
“…The temperature sensitivities of FBGs at 1552.3 nm, determined using the FiberPro interrogation unit, during the 1st and 2nd heat/cool cycles for the reference and coated FBGs were in the range of 9.7-9.9 pm K −1 respectively by considering a linear fit. The data reported in the literature for the temperature sensitivity of type-I Ge-B co-doped optical fibre grating was in the range of 9.19-10.69 pm K −1 [45,46]. Accepting the lower wavelength resolution of the FTNIR spectrometer when compared with the FiberPro interrogation unit, the corresponding temperature sensitivities for the coated and reference FBG sensors measured via the FTNIR spectrometer were in the range of 9.5-10.2 pm K −1 .…”
Section: Annealing the Au/pd Coatingsmentioning
confidence: 98%
“…, being S the norm of the matrix S containing the coefficients of sensitivities. In order to reduce the uncertainties in the discrimination, a small conditional number is desired [22]. Considering that the temperature and strain sensitivities of a φOTDR system are, in principle, similar to the ones of FBGs (i.e.…”
Section: Temperature-strain Discriminationmentioning
confidence: 99%