2023
DOI: 10.1016/j.jpba.2023.115317
|View full text |Cite
|
Sign up to set email alerts
|

In-syringe dispersive solid phase filter extraction cleanup followed by liquid chromatography-triple quadrupole mass spectrometry for fast determination of colchicine in plasma/urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…The proposed method demonstrated a linearity range of 0.04-20 ng/mL and limits of detection (LOD) and quantitation (LOQ) of 0.06 ng/mL and 0.2 ng/mL for colchicine in plasma and urine. Mean extraction yields at three different spiking levels in plasma and urine are quite reproducible (93.9-102.68%), with acceptable relative standard deviation (RSD) values [24]. Moreover, the investigation thoroughly validates the analytical approach by assessing matrix effect, stability, dilution integrity, and carryover.…”
Section: Solid-phase-based Extraction Proceduresmentioning
confidence: 67%
See 1 more Smart Citation
“…The proposed method demonstrated a linearity range of 0.04-20 ng/mL and limits of detection (LOD) and quantitation (LOQ) of 0.06 ng/mL and 0.2 ng/mL for colchicine in plasma and urine. Mean extraction yields at three different spiking levels in plasma and urine are quite reproducible (93.9-102.68%), with acceptable relative standard deviation (RSD) values [24]. Moreover, the investigation thoroughly validates the analytical approach by assessing matrix effect, stability, dilution integrity, and carryover.…”
Section: Solid-phase-based Extraction Proceduresmentioning
confidence: 67%
“…The approach, also known as dispersive micro-solid phase extraction (D-µ-SPE), utilizes small quantities (milligrams) of sorbent. Qian et al [24] proposed a fast and extremely precise approach for reliable colchicine measurement in plasma and urine. The method involves a combination of in-syringe d-SPE and LC-QqQ with ESI (d-SPE-ESI-LC-MS/MS) in MRM mode, demonstrating very good linearity and accuracy at therapeutic drug levels.…”
Section: Solid-phase-based Extraction Proceduresmentioning
confidence: 99%
“…The primary objective of this study was to establish a rapid and effective quantitation method for DIZ, TOZ, TZSO, TZS, and NICA in chicken muscle and eggs. In this study, we used an in-syringe DSPE, a widely utilized technique for rapid sample pretreatment [ 21 , 22 ]. The whole procedure is easy to operate and fast, involving extraction with ACN, the addition of NaCl to remove large amounts of protein from the samples, followed by the addition of a suitable sorbent and further n-hexane to eliminate both polar and fat-soluble interferences in the samples.…”
Section: Resultsmentioning
confidence: 99%