2018
DOI: 10.1016/j.rmed.2018.03.010
|View full text |Cite
|
Sign up to set email alerts
|

In vitro and clinical characterization of the valved holding chamber AeroChamber Plus ® Flow-Vu ® for administrating tiotropium Respimat ® in 1–5-year-old children with persistent asthmatic symptoms

Abstract: The trial was registered under NCT01634113 at http://www.clinicaltrials.gov.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 24 publications
1
7
0
Order By: Relevance
“…31 Furthermore, previous research reported larger MMADs than those measured in our study. [16][17][18] It is inferred that impactors used in previous research were not able to measure the range of PSD in SMI aerosols; Wachtel et al 17 also noted that approximately one quarter of the SMI label dose was collected at the microorifice collector (cut-off diameter: 0.54 mm) of the next-generation impactor at a flow of 30 L/min. In contrast, the MOUDI impactor utilized in our study can measure the particle size down to 0.056 mm and revealed the PSD of SMI aerosols < 0.54 mm.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…31 Furthermore, previous research reported larger MMADs than those measured in our study. [16][17][18] It is inferred that impactors used in previous research were not able to measure the range of PSD in SMI aerosols; Wachtel et al 17 also noted that approximately one quarter of the SMI label dose was collected at the microorifice collector (cut-off diameter: 0.54 mm) of the next-generation impactor at a flow of 30 L/min. In contrast, the MOUDI impactor utilized in our study can measure the particle size down to 0.056 mm and revealed the PSD of SMI aerosols < 0.54 mm.…”
Section: Discussionmentioning
confidence: 99%
“…Previous research has noted that SMIs can generate drug aerosols with a mass median aerodynamic diameter (MMAD) < 5 mm and an FPF > 60%. 2,[16][17][18] Moreover, because inhalation aids such as a spacer or a valved holding chamber (VHC) can improve the PSD and hand-breath coordination, pMDIs are recommended to be used along with an inhalation aid. 19,20 As for SMIs, studies have reported that drug delivery from an SMI with a VHC reduces fine particle masses, and the literature advises against the use of inhalation aids with an SMI for adults and older children.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations