2017
DOI: 10.1097/id.0000000000000533
|View full text |Cite
|
Sign up to set email alerts
|

In Vitro Microbiological Analysis of Bacterial Seal in Hybrid Zirconia Abutment Tapered Connection

Abstract: Hybrid zirconia abutments can create an effective seal at the tapered abutment-implant interface with a 30-N·cm installation torque.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 19 publications
0
1
0
2
Order By: Relevance
“…Factors that influence microleakage include IAI geometry, torque values, implant connection type, sterilizing methods, and use of adhesives and sealants 8,9) . Numerous in vivo and in vitro studies have examined microleakage of implants with different IAI geometry, confirming the high correlation between the type of implant-abutment connection and bacterial accumulation 6,[10][11][12][13][14][15][16][17][18][19] . While previous studies have focused on the leakage following definitive abutment placement, leakage during healing processes should also be investigated.…”
Section: Introductionmentioning
confidence: 78%
“…Factors that influence microleakage include IAI geometry, torque values, implant connection type, sterilizing methods, and use of adhesives and sealants 8,9) . Numerous in vivo and in vitro studies have examined microleakage of implants with different IAI geometry, confirming the high correlation between the type of implant-abutment connection and bacterial accumulation 6,[10][11][12][13][14][15][16][17][18][19] . While previous studies have focused on the leakage following definitive abutment placement, leakage during healing processes should also be investigated.…”
Section: Introductionmentioning
confidence: 78%
“…Como uma alternativa de promover tanto vantagens estéticas quanto mecânicas, têm sido utilizados componentes híbridos de zircônia com base em titânio 22 . Além de ter uma coloração favorável que potencializa a obtenção de um resultado estético, foi observada uma superioridade no comportamento biológico da zircônia quando em contato com os tecidos moles em relação aos componentes de titânio.…”
Section: Discussionunclassified
“…Além de ter uma coloração favorável que potencializa a obtenção de um resultado estético, foi observada uma superioridade no comportamento biológico da zircônia quando em contato com os tecidos moles em relação aos componentes de titânio. O uso de um componente personalizado em zircônia permite fazer ajustes sem a necessidade de trocar ou remover o componente, podendo assim adaptar o componente as remodelações do tecido mole que acontecem durante período de cicatrização 22 .…”
Section: Discussionunclassified