2018
DOI: 10.2147/ijn.s168731
|View full text |Cite
|
Sign up to set email alerts
|

In vivo toxicological evaluation of graphene oxide nanoplatelets for clinical application

Abstract: BackgroundGraphene is considered as a wonder material; it is the strongest material on the planet, super-elastic, and conductive. Its application in biomedicine is huge, with a multibillion-dollar industry, and will revolutionize the diagnostic and treatment of diseases. However, its safety and potential toxicity is the main challenge.MethodsThis study assessed the potential toxicity of graphene oxide nanoplatelets (GONs) in an in vivo animal model using systemic, hematological, biochemical, and histopathologi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
44
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 67 publications
(47 citation statements)
references
References 50 publications
1
44
0
2
Order By: Relevance
“…According to the tensile test results reported in Table 4, the tensile strength of PLLA increased by ca 21% and ca 25% when 0.4 and 0.8 wt% GO was added (Table 4). This reinforcing effect could be beneficial for applications were as little as 0.4 and 0.8 wt% GO can be incorporated in the polymeric matrix, in order not to be toxic towards human tissues 4,5 . The incorporation of 0.8 wt% GO led to an increase by ca 8% of Young’s modulus value when compared to unreinforced PLLA.…”
Section: Discussionmentioning
confidence: 95%
See 4 more Smart Citations
“…According to the tensile test results reported in Table 4, the tensile strength of PLLA increased by ca 21% and ca 25% when 0.4 and 0.8 wt% GO was added (Table 4). This reinforcing effect could be beneficial for applications were as little as 0.4 and 0.8 wt% GO can be incorporated in the polymeric matrix, in order not to be toxic towards human tissues 4,5 . The incorporation of 0.8 wt% GO led to an increase by ca 8% of Young’s modulus value when compared to unreinforced PLLA.…”
Section: Discussionmentioning
confidence: 95%
“…GO is utilized in nanocomposite fabrication due to its high compatibility with various polymer matrices and has shown its potential for biomedical applications in biosensors, drug delivery and orthopedic implants, attracting research interest in recent years, especially due to its desirable hydrophilicity and antibacterial activity 4 . GO has shown good biocompatibility with red blood cells 5 . The potential toxicity and biocompatibility, however, of GO remain controversial.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations