2021
DOI: 10.1016/j.matchemphys.2020.123788
|View full text |Cite
|
Sign up to set email alerts
|

Indenoquinoxalinone based conjugated polymer substrate for laccase biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 41 publications
0
3
0
Order By: Relevance
“…Most of the time the cross-linking agent glutaraldehyde is used in the covalent type of immobilization used in biosensors (Table 1). Cevher et al, 2021 reported the immobilization of the laccase on a PM1 electropolymer surface by covalent linkage via glutaraldehyde [66]. This biosensor was successfully applied for the stable detection of the indenoquinoxalinone from water.…”
Section: Covalent-based Laccase Immobilizationmentioning
confidence: 99%
“…Most of the time the cross-linking agent glutaraldehyde is used in the covalent type of immobilization used in biosensors (Table 1). Cevher et al, 2021 reported the immobilization of the laccase on a PM1 electropolymer surface by covalent linkage via glutaraldehyde [66]. This biosensor was successfully applied for the stable detection of the indenoquinoxalinone from water.…”
Section: Covalent-based Laccase Immobilizationmentioning
confidence: 99%
“… Composition Analytes Sensing behavior References 1 ZnO and Polyvinyl alcohol Glucose Tuneable potential with efficient parameters i.e. detection limit of 0.2 mM [ 76 ] 2 Indenoquinoxalinone based conjugated polymer Laccase The linear range of 0.005–0.175 mM, the limit of detection of 9.86 µM, and sensitivity of 153.6 µA/mMcm² [ 77 ] 3 1, 3, 6, 8-Tetraphenylpyrene and α , α ′-dibromo- p -xylene Trace ampicillin Limit of detection of 1.33 fg mL − 1 (3.30 f. M) with pi-pi inter-cation [ 78 ] 4 Bi-functional PEDOT NADH and lactate The linear range of 20–960 µM, the detection limit of 2.04, and sensitivity of 0.224 µA µM − 1 cm − 2 at the PEDOT-COOH50% interface [ 79 ] 5 Alginate based hydrogel E-coli Rapid and cost-effective with better parameters like the limit of detection 10 2 colonies forming unit per mL [ 80 ] 6 Chemically treated polyvinylchloride Ethanol Sensing range 0.01–42 mM, the limit of detection (LOD) of 0.0001 µM and stability for of 180 days at 4 °C [ 81 ] 7 PVC Membrane Antileukemia Drug Cytarabine Linearity range 1.0 × 10 − 6 –1.0 × 10 − 3 M at pH 2.8–4 with a detection limit of 5.5 × 10 − 7 M [ 82 ] 8 Polystyrene …”
Section: Biosensorsmentioning
confidence: 99%
“…Owing to the widespread applications such as organic solar cells (OSCs), 1,2 organic light emitting diodes (OLEDs), 3 sensors, 4,5 electrochromic devices (ECDs), 6,7 organic field effect transistors (OFETs) 8,9 and supercapacitors, 10,11 conjugated polymers (CPs) have received remarkable attention. Their organic-based nature provides several advantages such as low cost, solution processability, lightweight, and flexibility over inorganic ones.…”
mentioning
confidence: 99%