“…During August 2004 and July 2005 orbital reconstruction using individually preformed titanium mesh implants for the primary repair of orbital injuries was performed in 19 patients using a new technique described previously 32 . Only orbital floor and wall defects larger than 15 mm in diameter were repaired using preformed implants, due to the danger of late enophthalmus after resorption of the foils.…”
Section: Methodsmentioning
confidence: 99%
“…The ideal form of the injured orbital cavity was recalculated using the mirror image of the unaffected side 10 . The virtually reconstructed orbital form was then transformed into a model by a template machine as described previously 32,33 . The exact outline of the orbital defect was marked on the ideal orbital model.…”
Section: Methodsmentioning
confidence: 99%
“…A method of individual preforming of titanium mesh implants based on a virtual ideal orbital reconstruction has been described previously 32 . The results of primary orbital reconstruction using preoperatively individually formed orbital implants, and intraoperative computer-assisted control of exact placement of the implants are demonstrated.…”
“…During August 2004 and July 2005 orbital reconstruction using individually preformed titanium mesh implants for the primary repair of orbital injuries was performed in 19 patients using a new technique described previously 32 . Only orbital floor and wall defects larger than 15 mm in diameter were repaired using preformed implants, due to the danger of late enophthalmus after resorption of the foils.…”
Section: Methodsmentioning
confidence: 99%
“…The ideal form of the injured orbital cavity was recalculated using the mirror image of the unaffected side 10 . The virtually reconstructed orbital form was then transformed into a model by a template machine as described previously 32,33 . The exact outline of the orbital defect was marked on the ideal orbital model.…”
Section: Methodsmentioning
confidence: 99%
“…A method of individual preforming of titanium mesh implants based on a virtual ideal orbital reconstruction has been described previously 32 . The results of primary orbital reconstruction using preoperatively individually formed orbital implants, and intraoperative computer-assisted control of exact placement of the implants are demonstrated.…”
“…7. Als goldener Standard ist bei Verwendung derselben die Herstellung individueller Implantate [22,[33][34][35], ein guter Kompromiss ist jedoch die Verwendung von optimal präfabrizier-ten Titanmeshes, die -trotz interindividueller alters-und geschlechtsspezifischer Formvariabilität -anhand von CT-Analysen typischer Orbitaformen konstruiert wurden und insbesondere den posterioren Orbitaboden und die mediale Orbitawand berücksichtigen [15]. Eine intraoperative Individualisierung ist dank des segmentierten Designs (l " Abb.…”
Section: Laut Einer Kadaverstudie Liegt Die Präzision Der Präformiertenunclassified
“…4). Basierend auf den Analysen der Orbitaform [15,22] fokussiert sich in letzter Zeit das Interesse auf präfor-mierte Titanmeshes, die in der intraoperativen Handhabung Vorteile mit sich bringen sollen. Es war das Ziel der Studie, diese Vorteile zu analysieren.…”
Based on this experience and due to good intraoperative handling, the authors recommend the prefabricated titanium plate in the treatment of isolated orbital wall fractures or in combination with the medial wall despite the material costs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.