2006
DOI: 10.1016/j.tripleo.2006.02.031
|View full text |Cite
|
Sign up to set email alerts
|

Individual preformed titanium meshes for orbital fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
23
0
4

Year Published

2006
2006
2022
2022

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 75 publications
(27 citation statements)
references
References 29 publications
0
23
0
4
Order By: Relevance
“…During August 2004 and July 2005 orbital reconstruction using individually preformed titanium mesh implants for the primary repair of orbital injuries was performed in 19 patients using a new technique described previously 32 . Only orbital floor and wall defects larger than 15 mm in diameter were repaired using preformed implants, due to the danger of late enophthalmus after resorption of the foils.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…During August 2004 and July 2005 orbital reconstruction using individually preformed titanium mesh implants for the primary repair of orbital injuries was performed in 19 patients using a new technique described previously 32 . Only orbital floor and wall defects larger than 15 mm in diameter were repaired using preformed implants, due to the danger of late enophthalmus after resorption of the foils.…”
Section: Methodsmentioning
confidence: 99%
“…The ideal form of the injured orbital cavity was recalculated using the mirror image of the unaffected side 10 . The virtually reconstructed orbital form was then transformed into a model by a template machine as described previously 32,33 . The exact outline of the orbital defect was marked on the ideal orbital model.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…7. Als goldener Standard ist bei Verwendung derselben die Herstellung individueller Implantate [22,[33][34][35], ein guter Kompromiss ist jedoch die Verwendung von optimal präfabrizier-ten Titanmeshes, die -trotz interindividueller alters-und geschlechtsspezifischer Formvariabilität -anhand von CT-Analysen typischer Orbitaformen konstruiert wurden und insbesondere den posterioren Orbitaboden und die mediale Orbitawand berücksichtigen [15]. Eine intraoperative Individualisierung ist dank des segmentierten Designs (l " Abb.…”
Section: Laut Einer Kadaverstudie Liegt Die Präzision Der Präformiertenunclassified
“…4). Basierend auf den Analysen der Orbitaform [15,22] fokussiert sich in letzter Zeit das Interesse auf präfor-mierte Titanmeshes, die in der intraoperativen Handhabung Vorteile mit sich bringen sollen. Es war das Ziel der Studie, diese Vorteile zu analysieren.…”
unclassified