2003
DOI: 10.1002/elps.200305481
|View full text |Cite
|
Sign up to set email alerts
|

Infinite enantiomeric resolution of basic compounds using highly sulfated cyclodextrin as chiral selector in capillary electrophoresis

Abstract: Four chiral basic analytes, namely methadone, fluoxetine, venlafaxine, and tramadol, were selected as model compounds for investigating their stereoselective separation with highly sulfated gamma-cyclodextrin (HS gamma-CD) by capillary electrophoresis (CE)-UV and CE-mass spectrometry (MS). At high concentration of chiral selector, the preferentially bonded enantiomer migrated faster in the anodic mode to the detector and high resolutions were obtained for all analytes. In the cathodic mode, at lower highly sul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
67
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7
2
1

Relationship

4
6

Authors

Journals

citations
Cited by 63 publications
(67 citation statements)
references
References 61 publications
0
67
0
Order By: Relevance
“…For this purpose, HS-CD are particularly adapted for basic drug enantioseparation [12,18,43,[62][63][64]. Recently, the possibility to obtain rapid stereoselective analysis (,10 min) of amphetamine derivatives in plasma samples after a simple LLE and an HD injection was demonstrated.…”
Section: Stereoselective Analysismentioning
confidence: 99%
“…For this purpose, HS-CD are particularly adapted for basic drug enantioseparation [12,18,43,[62][63][64]. Recently, the possibility to obtain rapid stereoselective analysis (,10 min) of amphetamine derivatives in plasma samples after a simple LLE and an HD injection was demonstrated.…”
Section: Stereoselective Analysismentioning
confidence: 99%
“…The works included in this table are those in which the lowest LODs were obtained. MS detection has been employed in other works on chiral analysis by CE but LODs close to or above 10 25 M were generally obtained [125][126][127][128][129][130][131][132][133]. The basic instrumentation in CE-MS [134] allows, once the electrophoretic separation is performed, the introduction of the analytes in the mass spectrometer using an interface, usually a sheath liquid interface, which enables the establishment of the electrical contact and the nebulization of the solution.…”
Section: Alternative Detection Systems To On-column Uv-vis Absorptionmentioning
confidence: 99%
“…As LC remains the most widely used technique in the pharmaceutical industry, the discussion will be limited to this approach even if capillary electrophoresis presents some obvious advantages for fast enantioseparations. [9][10][11][12] In 2003, monolithic supports were coated with a chiral selector to perform fast enantioseparations. This material presents some interesting characteristics related to its bimodal structure of macropores and mesopores.…”
Section: 2mentioning
confidence: 99%