Influence of a window-type opening on the shear response of partially-grouted masonry shear walls

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…It also can be observed that the presence of interior vertical reinforcement bars did not deviate the crack pattern from the characteristic diagonal crack pattern of shear-dominated failures. This situation is contrary to the observed in studies carried out in shear walls made of multi-perforated clay bricks [35] and hollow clay blocks [36]. The progression of damage on Wall HCBW1A was also monitored with several strain gauges (SGs), which were stuck to horizontal reinforcement elements at the locations indicated in Figure 9a.…”
Section: Damage Progressionmentioning
confidence: 72%
See 1 more Smart Citation
“…It also can be observed that the presence of interior vertical reinforcement bars did not deviate the crack pattern from the characteristic diagonal crack pattern of shear-dominated failures. This situation is contrary to the observed in studies carried out in shear walls made of multi-perforated clay bricks [35] and hollow clay blocks [36]. The progression of damage on Wall HCBW1A was also monitored with several strain gauges (SGs), which were stuck to horizontal reinforcement elements at the locations indicated in Figure 9a.…”
Section: Damage Progressionmentioning
confidence: 72%
“…Considering this context, the idealized envelope curve and the ductility in a load direction were calculated herein with a conservative approach. Consequently, δ u was assumed as the deformation at maximum lateral resistance (δ Vmax ), as already done in previous studies [21,28,35,37,41]. This hypothesis is based on the fact that the post-peak response of masonry shear walls exhibits large variability and represents an undesirable damage state to achieve.…”
Section: Ductilitymentioning
confidence: 99%
“…As commented, the models predicted the tested walls' lateral in-plane resistance with an acceptable degree of precision. Therefore, the models' accuracy was also compared with that of selected shear expressions that have been studied in previous researches by the authors [3,4,35]. Particularly, the evaluated expressions were Shing et al [36] (Eq.…”
Section: Results Of Simulationsmentioning
confidence: 99%
“…According to recent studies [3,4], some shear estimation expressions give non-conservative results or large error ranges when assessing the resistance of bed-joint reinforced (BJR) PG-RM shear walls. In this sense, Araya-Letelier et al [5] have pointed out the need for more experimental evidence to fill out gaps in the knowledge and propose a more accurate shear design expression.…”
Section: Introductionmentioning
confidence: 99%
“…Equally, the flows of temperature and moist air that go through windows are reflected in the appearance of humidity by condensation [20]. Additionally, despite its lesser impact, one must also point to the roles played by windows and their perimeter elements in the causes of some problems related to fissurations and to the stability walls, especially those made with bricks [21].…”
Section: Introductionmentioning
confidence: 99%