2008
DOI: 10.1186/1472-6831-8-32
|View full text |Cite
|
Sign up to set email alerts
|

Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

Abstract: Background: The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

19
196
0
18

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 210 publications
(233 citation statements)
references
References 19 publications
19
196
0
18
Order By: Relevance
“…Many methods have been proposed to measure the primary stability, such as the Periotest, the resonant frequency and insertion torque, non-invasive tools which provide numerical values of the stability of implant through the measurement of stiffness in the bone/implant interface during or after installation 15 . The insertion torque is the angular moment of force required that the screw advances the screw thread inside the mounting hardware 16 , and provides fast and objective information about the quality of local bone 6-15 and the primary stability at surgery 6 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Many methods have been proposed to measure the primary stability, such as the Periotest, the resonant frequency and insertion torque, non-invasive tools which provide numerical values of the stability of implant through the measurement of stiffness in the bone/implant interface during or after installation 15 . The insertion torque is the angular moment of force required that the screw advances the screw thread inside the mounting hardware 16 , and provides fast and objective information about the quality of local bone 6-15 and the primary stability at surgery 6 .…”
Section: Discussionmentioning
confidence: 99%
“…Methods: Thirty-two Conexão ® implants were used: 8 conical (CC) (11.5 x 3.5 mm) and 24 cylindrical (11.5 x 3.75 mm) -8 external hexagon implants without surface treatment (MS), 8 external hexagon implants with double Porous treatment (MP), 8 internal hexagon implants with Porous treatment (CA). They were inserted in Nacional ® polyurethane in three densities (15, 20 and 40 PCF). The insertion torque (IT) (N.cm) was quantified using the digital Mackena ® torque meter, and the pullout force (PF) (N) by means of axial traction force with a 200 kg load cell, performed in a Universal Test Machine (Emic ® DL-10000) and the Tesc 3.13 software.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…En la actualidad se ha incrementado el número de estudios en implantología [1,2,3]; uno de sus enfoques consiste en comprender el comportamiento biomecánico y resistencia mecánica de los tejidos óseos [4], teniendo en cuenta el tipo, calidad y cantidad de los mismos [5]. El tejido óseo está formado por tejido óseo cortical, y tejido óseo trabecular [6].…”
Section: Introductionunclassified